4.4.2 To change the exhalation 

membranes 

The exhalation membranes are mounted on a 

dowel on the inside of the valve covers on each 

side of the mask body. Fig. 1/5. The covers 

should be changed whenever the membranes 

are changed.

•   Snap  the  valve  covers  off  the  membrane 

seats. Fig. 1/6

•   Prise off the membranes. 

•   Press the new membranes onto the dowels. 

Carefully check that the membranes are in 

contact with the membrane seats all round.

•   Press the valve covers into place. A clicking 

sound indicates that the cover has snapped 

into place.

4.4.3 To change the head harness

•  Detach  the  head  harness  by  pushing  the 

two connection points towards the filter 

attachment. 

•  Check that the straps are not twisted and 

snap on the new harness by putting each 

plastic swivel into the contoured slot and 

pulling it until it snaps in.

For  product/equipment  certified  to  AS/

NZS1716:2012;  for  advice,  see  also  AS/

NZS1715:2009  Use  and  Maintenance  of 

Respiratory Equipment. 

5. Technical specification

Inhalation resistance 

≈ 3 Pa, at 30 l/min.

Exhalation resistance

≈ 70 Pa, at 160 l/min. 

Materials

The material and pigments of the SR 100 mask 

body are approved for exposure to provisions, 

which minimizes the risk of contact allergies.

All plastic parts are marked with material codes 

and recycling symbols.

Shelf life

The half mask SR 100 have a shelf life of 10 

years and SR 90-2, SR 90-3, 5 years from the 

date of manufacture which can be established 

by examining the date wheel in the filter attach-

ment of the mask.

Size

Manufactured in two sizes, small/medium (S/M), 

and medium/large (M/L). 

Temperature range

Storage temperature: from -20 to +40 °C at a 

relative humidity (RH) below 90 %.

Service temperature: from -10 to +55 °C at a 

relative humidity (RH) below 90 %.

Weight

Small/medium: ≈ 165 g.

Medium/large: ≈ 175 g.

6. List of parts

The item numbers below refer to Fig. 1 at the 

end of these instructions.

Item Part No.  

Ordering No.

  Half mask SR 100 S/M 

H01-2112

  Half mask SR 100 M/L 

H01-2012

  Half mask SR 90-2 S/M 

H01-2312

  Half mask SR 90-2 M/L 

H01-2212

  Half mask SR 90-3 S/M 

H01-2712

  Half mask SR 90-3 M/L 

H01-2612

1.   Mask body 

-

2.  Filter attachment 

-

3.  Head harness SR 363, single strap   R01-2001

3.  Head harness SR 362, cradle strap  R01-2002

4.  Membrane seat 

-

5.  Exhalation membrane 

-

6.  Protective cap 

-

7.   Inhalation membrane 

-

8.  Pre-filter holder SR 5153 

R01-0604

9.  Test disc SR 322  

R01-0303

10. Pre-filter SR 221 

H02-0312

11. Particle filter P3 R, SR 510 

H02-1312

12. Gas filter A1, SR 217 

H02-2512

12. Gas filter A2, SR 218 

H02-2112

12. Gas filter AX, SR 298 

H02-2412

12. Gas filter ABE1, SR 315 

H02-3212

12. Gas filter ABE2, SR 294 

H02-3312

12. Gas filter K1, SR 316 

H02-4212

12. Gas filter K2, SR 295 

H02-4312

12. Gas filter ABEK1, SR 297 

H02-5312

  Combined filter filter 

  ABEK1-Hg-P3 R, SR 299-2 

H02-6512

  Membrane kit SR 369 for 

  SR 100, SR 90-3, fig. 3 

R01-2004

  Membrane kit SR 371 for SR 90-2  R01-2201

  Inhalation membrane  

-

  Exhalation membranes  

-

  Protective caps 

-

  Service kit SR 100, SR 90-3, fig. 4   R01-2005

  Service kit SR 90-2 

R01-2202

  Head harness  

-

  Membrane kit  

-

  Pre-filter holder  

-

  Protective hood SR 64, fig. 5  

H09-0301

  Protective hood SR 345, fig. 6 

H09-1012

  Protective hood SR 346, fig. 7 

H09-1112

Summary of Contents for H01-2012

Page 1: ...he SR 307 compressed air attachment which then serves as a breathing apparatus with continuous flow for connection to a compressed air supply A pre filter holder is supplied Best stored in box SR 230 or storage case SR 339 P01H 2018 Rev 09 20160816 Product Model No Ordering No Half mask SR 100 S M H01 2112 SR 100 M L H01 2012 SR 100 L XL H01 2812 Product Description Technical specification A Mask ...

Page 2: ...nt The equipment must not be used Ifyoucannotmake themaskatightfitduring the fitting test If the ambient air does not have a normal oxygen content If the pollutants are unknown or lack ad equate warning properties In environments that are Immediately Dan gerous to Life and Health IDLH With oxygen or oxygen enriched air If you find that breathing is difficult If you experience dizziness nausea or o...

Page 3: ...in it in the space between the lower lip of the particle filter and the small tab moulded into the side of the gas filter Push firmly and twist the coin until the filter pops off Fig 1b 2 3 4 Pre filter SR 221 TheSundströmpre filterSR221isnotaprotec tive element and can never be used as primary protection or as a substitute for a particle filter It is designed to prevent nuisance particulates from...

Page 4: ...es SR 5226 which clean and disinfect are recommended for daily care Ifthemaskisheavilysoiled useawarm up to 40 C mild soap solution and a soft brush followed by rinsing with clean water and drying in air at room temperature Proceed as follows Remove the filter the covers for the ex halation valves and the membranes the inhalationmembraneandtheheadharness Optional The harness can be washed but take...

Page 5: ...filter attach ment of the mask Size Manufacturedintwosizes small medium S M and medium large M L Temperature range Storage temperature from 20 to 40 C at a relative humidity RH below 90 Service temperature from 10 to 55 C at a relative humidity RH below 90 Weight Small medium 165 g Medium large 175 g 6 List of parts The item numbers below refer to Fig 1 at the end of these instructions Item Part N...

Page 6: ...ser instructions Date wheel Recycling symbol CEapprovedbyINSPECCertificationLtd 8 Approvals CE EN The half masks SR 100 SR 90 3 and SR 90 2 are approved in accordance with EN 140 1998 The EC type approval certificate has been issued by Notified Body 0194 For the address see the reverse side of the user instructions Australian StandardsMark The half masks SR 100 SR 90 3 and SR 90 2 are testedandcer...

Reviews: