costs. In order to achieve this, a wide surface of the heating elements have to be
selected. Ideally for low-temperature under-floor heating and wall heating 35 °C
flow-temperature is used. Furthermore low temperature radiant heat guarantees
maximum comfort. With conventional radiator heating, a flow temperature of max. 55
°C inlet temperature should be chosen.
1.6 Hot water with the heat pump
2. Installation system drawing
2.1. Heating / Hot water
Ground to water
If one does not select an individual Heat Recovery&Ventilation Hot Water Heat Pump
for the water heating from exhaust air, heating the water with the heating heat pump
is recommended. As a rule of thumb one should plan an additional heating capacity
of approx. 0,25 kW per person. SUNDEZ offers several efficient solutions, which
depending on the heat pump type and heating system, can be used effectively.