Page 12
ELITE SERIES
5.1
North American 60 Hz Power Options
North American 2-Pump Models (60 Hz)
240v/40A*
240v/50A**
240v/60A***
Voltage:
240 VAC
240 VAC
240 VAC
# of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
Circuit Breaker:
40A*, 2-Pole
50A**, 2-Pole
60A***, 2-Pole
*
In 40A configuration, the heater
will not operate
while either jets pump is
running in high speed.
Note: pump 2 runs only in high speed.
** In 50A configuration, the heater
will not operate
while both jets pumps
are running in high speed.
Note: pump 2 runs only in high speed.
This
is the factory setting.
*** In 60A configuration, the heater
will operate
while both jets pumps are
running in high speed.
Note: pump 2 runs only in high speed.
5.2
Export 50 Hz Power Options
Export 2-Pump Models (50 Hz)
230v/20A*
230v/30A**
230v/40A***
Voltage:
230 VAC
230 VAC
230 VAC
# of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
Circuit Breaker:
20A*
30A**
40A***
* In 20A configuration, the heater
will not operate
while either jets pump is
running in high speed.
This is the factory setting
.
Note: pump 2 runs
only in high speed.
** In 30A configuration, the heater
will not operate
while both jets pumps
are running in high speed.
Note: pump 2 runs only in high speed.
*** In 40A configuration, the heater
will operate
while both jets pump are
running in high speed.
Note: pump 2 runs only in high speed.