Suncourt Airiva Manual Download Page 1

IMPORTANT WARNINGS  

IMPORTANT SAFETY INSTRUCTIONS  

Suncourt recommends professional installation of the Airiva (or by an accomplished DIY person)  

Please read and save these entire instructions before starting the installation.  

WARNING 

To reduce the risk of fire or electrical shock, do not use this fan device with a speed control of any 

kind. This device is for general ventilating use only. Do not use with hazardous, toxic or flammable vapors.  

WARNING 

To reduce the risk of fire, electric shock or injury to persons or animals, observe the following: 

Use this unit only in the manner intended by the manufacturer. If you have any questions or doubts, contact a 
qualified installer or Suncourt Inc. Before servicing or cleaning this unit, disconnect the power by unplugging it 
from the 110-120 Volt AC outlet. If a suitable Ground Fault Interrupter (GFI) 110-120 Volt AC grounded outlet 
is not within reach of the Airiva™ power cord, a new GFI outlet needs to be installed. The installation of this 
outlet must be done by a qualified person(s) in accordance with all applicable Codes and Standards. The Airiva 
is equipped with a grounded plug. This safety feature must never be defeated.  

WARNING 

For your safety and protection follow all instructions and adhere to applicable safety, building and 

electrical codes.  

WARNING

 Install this product inside a building or dwelling only.  

WARNING 

Do not operate this product without ductwork or approved grilles being installed at the fan 

openings to prevent contact with the fans. Contact with the operating fans will cause serious injury.  

WARNING 

Do not install this product where it can come in contact with water from flooding or otherwise.  

WARNING 

Protect the outside vent hoods from ingress of water from rain or other sources. 

WARNING 

Never expose this product to air temperatures over 120°F (49°C).  

INSTALLATION AND MAINTENANCE INSTRUCTIONS 

Suncourt recommends installation of the Airiva™ by a professional. 

Please read and save these instructions in their entirety before starting the installation. 

WHERE AND HOW TO MOUNT

  

The Airiva™ should be mounted on shelf brackets that can easily support 75lbs. 

DO NOT Set the Airiva™ flat on a shelf. Condensation will occur between the surface of the Airiva™ and the 
shelf.  

The minimum mounting height should be 8" off the floor to provide clearance for the condensate drain. For 
convenience when servicing, mounting the Airiva™ at chest height is recommended. 

The Airiva should be mounted such that the latches for the door are on top. The hinges for the door should be 
on the bottom of the unit and slightly hanging over the stand or shelf.  

Summary of Contents for Airiva

Page 1: ... protection follow all instructions and adhere to applicable safety building and electrical codes WARNING Install this product inside a building or dwelling only WARNING Do not operate this product without ductwork or approved grilles being installed at the fan openings to prevent contact with the fans Contact with the operating fans will cause serious injury WARNING Do not install this product wh...

Page 2: ...iriva you should install the drain You will need to make a 5 8 diameter hole in the bottom of the Airiva at the lowest point The Airiva deserves its own ducts forced air system connection is a distant second choice only STANDARD DUCT CONNECTIONS The fresh outside air intake and stale air exhaust ducts should be kept as short as possible On the outside of your home you will need to install hoods to...

Page 3: ...ve the 2 5 16 hex head screws from the fan mounting bracket and remove the mounting brackets Flip the fan around and re secure it with the 2 mounting brackets and screws Re connect the quick connectors and the airflow direction change is complete Figure 2 displays the duct connections if the stale air fan is reversed and Figure 3 shows the duct connections if the fresh air fan is reversed Please n...

Page 4: ...used with a 6 24 VAC damper This damper will be installed in a T fitting on the fresh air intake side of the Airiva When the fresh air to the house is below 45 degrees F 4 degrees C it will open the damper allowing some warm house air to mix with the incoming cold fresh air This allows for an uninterrupted supply of fresh air while avoiding freezing of the unit s core The Suncourt ZO106P Zone Damp...

Page 5: ...Place each plate alternating the airflow channels on each layer Lock the top plate in place with the metal rods being careful not to bend them Clean the screens of the outside vents as necessary ...

Page 6: ......

Page 7: ...bills Cause excessive water collection inside the Airiva Normally no water will collect in the Airiva except on very high outside humidity days 85 or higher and an indoor air conditioned temperature of less than 80º F or 27º C The Airiva heat exchanger core will accumulate an excessive amount of dust and dirt as a result of excessive airflow Connecting the Airiva to the air supply and air return d...

Page 8: ...stale air These motorized dampers are in addition to two manual dampers to be installed in the same ducts for airflow balancing when the forced air system is NOT operating The manual dampers must be balanced first before balancing the motorized dampers The balancing of the manual dampers must be performed when the main forced air system is not operating These manual dampers may be installed either...

Page 9: ... running You should find this connection location on the wiring diagram inside the enclosure cover of your furnace and or in the furnace installation manual You may install the stud mount transformer in one of several knockouts on your furnace The primary connections will be inside the furnace for safety Connect the secondary 24 VAC power to both ZoneMaster motorized dampers in parallel Never conn...

Page 10: ... return air duct 14 Once these two dampers have been initially calibrated repeat the calibration for both dampers since the position of one damper may somewhat affect airflow through the other 15 When you are satisfied that both airflows are within specification tightly secure the Calibration Control wing nuts and instruct the customer to never alter these calibrated settings YOU WILL HAVE TWO MAN...

Page 11: ...t apply to defects resulting from alteration abuse accidental damage unauthorized repair or misuse of the unit c a defective unit must be returned prepaid with proof of purchase after obtaining a return good authorization from Suncourt Inc The unit must be returned in the original packaging and packaged as per enclosed instructions This warranty is given in lieu of all other warranties guarantees ...

Page 12: ...nufacturer reserves the right to change product specifications without notice Airiva is a Trade Mark of Suncourt Inc SUNCOURT INC P O Box 40 500 West Second Avenue Durant IA 52747 0040 USA 1 800 999 FANS ...

Reviews: