Page 1: ...Service Manual Refrigerators 20060328...

Page 2: ...m frontal board of signaling B 13 Electronic chips configuration signaling B 14 Electronic chips configuration signaling alarm system ADI B 15 SECTION C REFRIGERATION SYSTEMS AND SERVICE C 1 Safety in...

Page 3: ...ance with the electric code the green cable is dedicated to such function Removing the ground cable or the plug s contact pin will result into potential DANGER for the consumer 6 In every moment respe...

Page 4: ...SERIAL LABEL INFORMATION PAGE A2 SERIAL NUMBER LABEL LOCATION...

Page 5: ...the refrigerator REMEMBER the temperature inside the refrigerator is affected by the door gaskets closure the frost accumulation in the evaporator the service load the room temperature the percentage...

Page 6: ...ean the inside with a warm water and sodium bicarbonate solution dissolve one sodium bicarbonate teaspoon per half liter of water Then rinse and dry the refrigerator making sure excess water is elimin...

Page 7: ...the plastic counter gate and do the same operation in the whole gasket contour until it is completely out 5 Once the gasket is out clean the door foam residues 6 Take a new gasket and in one of the c...

Page 8: ...double isolation and need no ground wire Make sure the wall plug is the country standard and is adequately grounded according to the rules in force RELAY AND OVERLOAD PROTECTOR Magnetic Relay The star...

Page 9: ...replaced an identical model should be used with the same part number AN OVERLOAD PROTECTOR SHOULD NEVER BE REPLACED WITH ANOTHER NON AUTHORIZED PART NUMBER An inadequate protector may cause a motor b...

Page 10: ...d through the overload protector as indicated in figure B3 Figure B3 Electric Circuit To verify the relay 1 Disconnect the refrigerator s feed electric cable 2 Remove the relay cap disconnect the thre...

Page 11: ...apacitor cables 3 Discharge the capacitor by short circuiting the terminals with a 500 K resistor 1 watt for one minute 4 With an ohmmeter verify the resistance through the capacitor wire terminals wi...

Page 12: ...ilar to a new start after a temporary electric power cut off 2 As the PTC relay opens compressor start circuit whether it has ran or not the overload protector has been mapped out and calibrated to op...

Page 13: ...ERATURE CONTROL The thermostats are the devices allowing the refrigerator temperature adjustments thanks to the mechanic internal components propeled by the answer of a refrigerant contained in the se...

Page 14: ...orator plate right upper zone Automatic defrost models Constant Environment Differential Figure B7 C Used in the two doors frost free models with Multiflow system and for any position of the knob from...

Page 15: ...ring specifications 9 Assemble the thermostat electric installation as shown in the electric diagram in the rear part of the refrigerator 10 Re assemble the control box 11 Put the thermostat bulb in t...

Page 16: ...terals to manage the quantity of air flowing in both compartments thus controlling the freezer temperature and the air injection in the Multiflow conduit to the fridge To access the fan set motor wing...

Page 17: ...PAGE B10 Figure B9 Forced ventilation systems Figure B8 Forced ventilation systems in frost free models B TROPICALIZED A CONVENTIONAL C MULTIFLOW TROPICALIZED MULTIFLOW TROPICALIZED CONVENTIONAL AND...

Page 18: ...tially only if the evaporator temperature is under the water freezing point 9 2 C and disconnecting it when the evaporator temperature is higher than the water freezing point 8 2 C to guarantee the co...

Page 19: ...caps again 8 Put the respective shelves in their positions Note As of August 1997 the resistance connection is made directly in the control box as shown in the cables diagram Replacement of freezer d...

Page 20: ...s These elements are identified in the frontal board with letters and icons as follows C Compressor turned on when it is functioning D Defrosting turned on when the defrosting cycle is activated F Fan...

Page 21: ...alarm board activated through the auto diagnosis system ADI which indicates eventual dysfunctions in the product performance through pilot lights blinking for operating conditions Once the anomaly is...

Page 22: ...C CARDS CONFIGURATION SIGNALING ALARN ADI SYSTEM With the ADI SYSTEM the display provides the technician relevant information to attend refrigerator failures It will not indicate where to locate the f...

Page 23: ...propriately depending on the refrigerator s model One of the terminals has a yellow or light blue indication This signaling point will always be in a two cable terminal and in the card in the respecti...

Page 24: ...quid a situation followed by several circumstances may cause the compressor shield joints separations A hydraulic blocking prevents the compressor run This condition is known as blocked rotor the elec...

Page 25: ...t move the tubing while welding is solidified CAUTION Use damp clothes during the heat application to prevent transmission to surfaces other than the welded joint Use a ceramic plate as a heat deflec...

Page 26: ...ile the compressor works the refrigerant heat flows by the perimetric tube thus heating the cabinet frontal external part and avoiding condensation Figure C4 PAGE C3 A Automatic manual defrosting B Au...

Page 27: ...enser will heat and the power will grow In case of refrigerant loss in the low pressure side causing total loss of refrigerant the compressor will work but without refrigeration The suction pressure w...

Page 28: ...frigerant used to clean the system must be recovered For this reason it is recommended to use dry nitrogen in this cleaning process CAUTION Use dries nitrogen carefully when cleaning systems Make sure...

Page 29: ...door The service of manual defrosting evaporator and the set of capillary tube and suction line are carried out as one set 1 Disconnect the electric current unit 2 Take away the defrosting water tray...

Page 30: ...acuation and reload How to replace the flapped evaporator tube suction in frost free models 1 Disconnect the electric current unit 2 Take away all the refrigerator internal components Glass shelves et...

Page 31: ...il it touches isolation completely 20 Put condenser in position and screw again 21 Place the refrigerator vertically replace the dehydrator filter as shown in this manual 22 Make evacuation and load p...

Page 32: ...tem If it is necessary replace both elements 5 Clean the refrigeration system and eliminate dirt and humidity completely 6 Install the new tubing extension clean the joints and apply good quality weld...

Page 33: ...n adequate size process tube adapter in the process tube If the compressor was not replaced cut the process tube with a tube cutter leaving as much tube as possible though removing the line extraction...

Page 34: ...ter and raise the 4 5 kPa pressure over the manometric pressure to a room temperature CAUTION Maintain without exceeding this 4 5 kPa increase in the manometric pressure during the system loading WARN...

Page 35: ...the condenser With the compressor working the condenser should be hot with a temperature gradual reduction from the entrance to the condenser exit 4 Do the door gaskets close appropriately Prove with...

Page 36: ...r D Compressor starts Works in very short cycles 1 Thermal protector 2 Defective thermostat 3 High pressure 4 Gas load surplus 1 See part C 2 Replace 3 Lack of ventilation in the compressor 4 Apply re...

Page 37: ...ances producing heat stoves 7 Use it according to indications in the refrigerator s manual 8 Apply the recommended load 9 Locate the escape and re load 10 Put the bulb properly as indicated in the ser...

Page 38: ...ntrance peak that leads liquid to a filling bowl An obturant drop around the entrance water tube prevents air and humidity entrance to the freezer compartment FRONTAL CAP A plastic molded decorative f...

Page 39: ...s with the icemaker thermostat and functions as a security device The original heater is incorporated in its position but can be taken away for replacement The spare heater is fastened to the mold thr...

Page 40: ...ter valve set The water valve is propelled by a solenoid and when activated leaves the water pass from the feeding line to the ice mold The quantity of water is directly proportional to the period dur...

Page 41: ...damage A thermal mastic adhesive tape has been placed where the thermostat is mounted against the mold A joint restrains the water pass to the support box Signaling arm and system of rods The signalin...

Page 42: ...s the only adjustable component in the icemaker 3 Closure switch Stops the manufacturer operation when the container is full of ice Cam synchronizer and coupler Three different cams are combined in a...

Page 43: ...ultaneously A D shaped opening in the gear is adjusted to the cam synchronizer cube The rear side separators of the gear restrain it to press against the mounting plate See figure D10 Figure D10 Gear...

Page 44: ...CATOLOGO DE PARTES SPARE PARTS CATALOG...

Page 45: ...trando la siguiente informaci n Modelo del refrigerador Mes y a o de fabricaci n N mero de parte Descripci n de la parte Cantidad a solicitar IF YOU NEED TO BUY SPARE PARTS 1 Identify the SERVICE CODE...

Page 46: ...descripciones n meros de parte actualizaci n de cantidades correcciones etc Dichos cambios no afectan el uso del cat logo en productos fabricados en fechas anteriores al cambio UPDATING OF INFORMATION...

Page 47: ...c ENSAMBLE ACCESORIOS INTERNOS ASSEMBLY INTERNAL ACCESORIES SNR10TFPA SNR12TFOA SNR12TFPA SNR13TFOA SNR13TFPA SNR14TFPA...

Page 48: ...F35 37 40 BLACK SB701644 1 1 1 1 1 EMPAQUE MAGNETICO INFERIOR F28 BLANCO MAGNETIC GASKET LOWER DOOR F28 WHITE SB701633 EMPAQUE MAGNETICO INFERIOR F28 NEGRO MAGNETIC GASKET LOWER DOOR F28 BLACK SB7016...

Page 49: ...65mm BLANCO VEGETABLES CRISPER 665mm WHITE SB197059 RSC 1 1 25 BANDEJA CARNES TRANSPARENTE MEAT DRAWER TRANSPARENT SB196738 RSC 1 1 1 1 PARRILLA PLASTICA ENFRIADOR 595mm TRANSPARENTE REFRIGERATOR PLAS...

Page 50: ...f ENSAMBLE ACCESORIOS PARA PUERTA ASSEMBLY DOOR ACCESORIES SNR10TFPA SNR12TFOA SNR12TFPA SNR13TFOA SNR13TFPA SNR14TFPA...

Page 51: ...ROSS RAIL COVER 595mm BEIGE SB196933 RSC COBERTOR MEDIO TRAVESA O CURVO 595mm GRIS CURVED MIDDLE CROSS RAIL COVER 595mm GRAY SB196995 RSC COBERTOR MEDIO TRAVESA O CURVO 595mm NEGRO CURVED MIDDLE CROSS...

Page 52: ...HANDLE ATTACHMENT PLATE SB197217 RSC 2 2 2 2 COBERTOR DISPLAY OP NEGRO DISPLAY COVER 0P BLACK SB197015 RSC COBERTOR DISPLAY OP BEIGE DISPLAY COVER 0P BEIGE SB197402 RSC COBERTOR DISPLAY OP GRIS DISPLA...

Page 53: ...i ENSAMBLE COMPRESOR Y BASE ASSEMBLY COMPRESSOR AND SUPPORT SNR10TFPA SNR12TFOA SNR12TFPA SNR13TFOA SNR13TFPA SNR14TFPA...

Page 54: ...5G 2 VIAS 2 WAY FILTER 7 5G SB901304 1 7 DESHIDRATADOR 15G 2 VIAS 2 WAY FILTER 15G SB901303 1 1 1 1 1 8 REMACHE CIEGO DOMO CRS 1 8 X 3 8 BLIND RIVET DOME CRS 1 8 X 3 8 SB913605 4 4 4 4 4 4 9 TEMPORIZA...

Page 55: ...k ENSAMBLE CONDENSADOR ASSEMBLY CONDENSER SNR10TFPA SNR12TFOA SNR12TFPA SNR13TFOA SNR13TFPA SNR14TFPA...

Page 56: ...TIDAD QUANTITY SNR10TFPA SNR12TFOA SNR12TFPA SNR13TFOA SNR13TFPA SNR14TFPA 1 GAZA PLASTICA PARA CONDENSADOR PLASTIC BRAKET FOR CONDENSER SB191125 RSC 4 4 4 4 4 4 2 TORNILLO 8 15x1 SCREW 8 15x1 SB91302...

Page 57: ...m ENSAMBLE COMPONENTES CONGELADOR ASSEMBLY FREEZER COMPONENTS SNR10TFPA SNR12TFOA SNR12TFPA SNR13TFOA SNR13TFPA SNR14TFPA...

Page 58: ...2 2 13 BLOQUE CONTROL FLUJO PSE CONTROL FLOW BLOCK PSE SB 710108 2 2 2 2 2 2 RESISTENCIA DESHIELO F565mm 200W 120V ALTA EFICIENCIA DEFROST HEATER F565mm 200W 120V HIGH EFFICIENCY SB 914264 1 14 RESIST...

Page 59: ...o ENSAMBLE CAJA DE CONTROL Y DUCTO MULTIFLUJO ASSEMBLY CONTROL BOX AND MULTIFLOW DUCT SNR10TFPA SNR12TFOA SNR12TFPA SNR13TFOA SNR13TFPA SNR14TFPA...

Page 60: ...TROL BOX KNOB WHITE SB 197038 RSC 1 1 1 1 1 1 5 PORTA LAMPARA SOCKET SB 914252 1 1 1 1 1 1 6 LAMPARA 15W 110 120V LAMP 15W 110 120V SB 914005 1 1 1 1 1 1 7 TERMOSTATO F THERMOSTAT F SB 901721 1 1 1 1...

Page 61: ...O THERMOFUSE TERMOFUSIBLE G V G V BL A BR C R R W B BL A G V W B W B R R BR C BL A W B G V W B G V BK N G V GREEN VERDE BR C BROWN CAF R R RED ROJO BL A BLUE AZUL W B WHITE BLANCO BK N BLACK NEGRO W B...

Page 62: ...GHT IN FREEZER DESHIELO AUTOMATICO CONGELADOR CON LUZ F35 F37 F40 FREEZER CONGELADOR NC 2 1 4 NO 3 M RUNNING CAPACITOR CAPACITOR MARCHA BL A F CL R R W B K N W B BK N S R C G V G V THERMOSTAT TERMOSTA...

Page 63: ...TOR FREEZER AUTOMATIC DEFROST HAD BEEN ADDED THE SNR12TFOA MODEL 02 06 PART NUMBER OF ITEM 1 WAS MODIFIED IT WAS 196801 RSC IT WAS MODIFIED BY 197629 RSC 02 06 PART NUMBER OF ITEM 3 REFRIG DOOR F37 WH...

Page 64: ...Inc doing business as Jarden Consumer Solutions All rights reserved Sunbeam is a registered trademark of Sunbeam Products Inc used under license Distributed by Petters Consumer Brands LLC 4400 Baker R...