9.4
CUSTOM CONTROL CABLE AND 3RD-PARTY SPECIFICATIONS
The LED fixture can be used with most analog 0 -10 Volt DC communication systems.
For analog control, please follow the chart below on custom wiring on the fixture side.
PIN OUT (FIXTURE SIDE RJ45 6P4C)
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
CONNECTION
N/C
N/C
Signal
GND
GND
Signal
N/C
N/C
DIMMING SEQUENCE
NC/Error State
OFF
ON
CONTROL RANGE
RECOMMENDED
SIGNAL (VDC)
0.0
2.5
5.0
5.0 V - 10.0 V
FIXTURE RESPONSE
(% Output of Fixture)
0%
0%
50%
50% - 100%
9.5
CONTENTS OF THE REPEATER BUS CONNECTION KIT NOT INCLUDED. KIT SOLD SEPARATELY.
The e-Series adapter interconnect kit contains the following items:
HGC906712: 1) 1x Gavita e-Series LED Adapter Interconnect Cable 80 ft Kit
2) 6x RJ45 terminal connectors
HGC906714: 1) 1x Gavita e-Series LED Adapter Interconnect Cable 80 ft Kit
2) 3x RJ45 + 3x RJ14 terminal connectors
OPTIONAL: HGC906721: Gavita e-Series LED Adapter Interconnect Cable 3 Way Splitter RJ45
HGC906720: Interconnect Cable Crimper
9.6
PREPARATION FOR USE WITH A CONTROLLER
Locate the unstripped interconnect cable.
Cut the cable to the desired length and strip both ends using a crimp tool (e.g. product #HGC906720, sold separately).
Insert the cable end into the RJ connectors and use the crimp tool to finish the assembly.
9.7
CONNECTING THE LED FIXTURE TO THE MAINS
Make sure power cords:
1.
Are
not
concealed or extended through a wall, floor, ceiling, or other parts of the building structure.
2.
Are
not
located above a suspended ceiling or dropped ceiling.
3.
Are
not
permanently affixed to the building structure.
4.
Are routed so that they are not subject to strain and are protected from physical damage.
5.
Are visible over their entire length.
6.
Are used within their rated ampacity as determined for the maximum temperature of the installed environment specified in the instructions.
Ensure the cord is not coiled and does not touch any hot surfaces.
If external switching gear is used to switch the fixture, ensure it can cope with the inrush current of the fixture.
Always use a double pole contactor suitable for switching a capacitive load.
Never use household timers to switch the fixture!
Switch off main power.
Connect the power cable to the mains. The Sun System RS 1850 LED 120-240 V power cables connect to a NEMA Receptacle.
The Sun System RS 1850 LED 277 V uses an open-end cable.
Cable Description Sun System RS 1850 LED 277 V
WIRE
277 V
White
Neutral (N)
Black
Phase (L)
Green
Ground ( )
+Signal
(0-10V)
GND/VE
N/C
N/C
1 2 3 4 5 6 7 8