![Sun Microsystems Sun StorEdge T3 Installation, Operation And Service Manual Download Page 101](http://html.mh-extra.com/html/sun-microsystems/sun-storedge-t3/sun-storedge-t3_installation-operation-and-service-manual_1393010101.webp)
Chapter 4
Troubleshooting
4-7
4.1.4.3
Interconnect Card LEDs
Each interconnect card has a status LED for each interconnect cable.
lists
the possible interconnect card status LED states with descriptions of each state.
FIGURE 4-3
Interconnect Card LEDs
Note –
See Chapter 5 for instructions on how to service a failed interconnect card.
TABLE 4-3
Interconnect Card LED Descriptions
Interconnect Card
Status LED
(green or amber)
Description
Off
• Interconnect card not installed (not recognized)
Green-solid
• Interconnect card OK
• Cable OK (if present)
Green-slow blink
• Interconnect card OK
• Cable bad; OK to replace cable
Amber-solid
• Interconnect card firmware download in progress
Amber-slow blink
• Interconnect card failure; OK to replace interconnect card
Note—Verify an interconnect card or cable failure using the
CLI or Component Manager.
LED 1 LED 2
Interconnect
Interconnect card 2
LED 1
LED 2
card 1
Summary of Contents for Sun StorEdge T3
Page 6: ...vi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 14: ...xiv Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 26: ...xxvi Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 38: ...1 12 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 84: ...2 46 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 104: ...4 10 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...
Page 134: ...A 6 Sun StorEdge T3 Disk Tray Installation Operation and Service Manual July 2000 ...