![Sun Microsystems SUN-FOSC-ZT702 Series User Manual Download Page 2](http://html1.mh-extra.com/html/sun-microsystems/sun-fosc-zt702-series/sun-fosc-zt702-series_user-manual_1392425002.webp)
Fiber Optic Solutions Provider
1/3
www.suntelecom.cn • +86-21-60138638 • [email protected]
1. Scope of application
This Installation Manual is suit for the Fiber Optic Splice Closure (Hereafter
abbreviated as FOSC), as the guidance of proper installation. The scope of
application is: aerial, underground, pipeline, handhole.
2. Applicable temperature
-1
~
+45
℃
(Temperature for operation)
-50
~
+70
℃
(Temperature for storage and transportation)
-40
~
+65
℃
(The ambient temperature ranges)
3. Stripping fiber cable
3.1
When branch cable stripping, should put the length of the fiber optic cable
skin peeled off as about 1200 mm, Reserve reinforced core in 60 mm length
and cut off the unnecessary ones. See figure 1
3.2
When straight-through cable stripping, should put the length of the fiber
optic cable skin peeled off as about 1600 mm, Reserve reinforced core in 60
mm length and cut off the unnecessary ones. See figure 2
4. Fixing fiber cable.
4.1
Fixed cable and heat shrinkable fixing sleeve according to the picture
below. See figure 3, figure5.
1200
mm
Figure 1
1600
mm
Figure 2
Figure 3