Chapter 2
Installing the Sun Fire T2000 Server
15
FIGURE 2-4
Attaching a Mounting Bracket to the Chassis
b. With the heads of the three locating pins protruding though the three keyed
openings in the mounting bracket, pull the mounting bracket toward the front
of the chassis until the bracket locks into place with an audible
click
.
c. Verify that all three locating pins are trapped in the keyed openings and that
the rear locating pin has engaged the mounting bracket lock, as shown in the
right side of
3. Attach the second mounting bracket to the left side of the Sun Fire T2000 chassis.
4. Determine which rack hole numbers to use when attaching the slide rails to the
rack posts.
The Sun Fire T2000 server is two rack units tall (2 RU). The slide rails will occupy
the lower half of the 2 RU space.