8
Sun Fire T2000 Server Installation Guide
• April 2006
Slide Rail Assembly Notes
The rackmount kit has two
slide rail assemblies
. A slide rail assembly can be installed
on either the right or left side of the rack.
Each slide rail assembly consists of a three-section slide rail and a removeable
mounting bracket (
).
FIGURE 1-4
Sections of the Slide Rail Assembly
■
The
front
,
middle
, and
rear
sections form the
slide rail
. The middle and rear sections
have holes for mounting screws and adjust to fit rack depths from 24 in (61 cm) to
36.5 in (93 cm). The front section can be extended to allow movement of the
server out of the rack.
■
The removeable
mounting bracket
slides 14 in (36 cm) out of the slide rail, then
locks in place. If you unlock the mounting bracket at this point, it slides an
additional 12 in (30 cm) before separating from the slide rail. You can then mount
the mounting bracket to the right or left side of the Sun Fire T2000 chassis.
■
Note that there are a total of five locks (
) in a slide rail assembly. Four
are on the mounting bracket. One lock is on the front section of the slide rail. The
uses of these locks are described in the installation procedure in
Mounting bracket
Rear section
Front section
Middle section
Summary of Contents for Sun Fire T200
Page 6: ...vi Sun Fire T2000 Server Installation Guide April 2006...
Page 10: ...x Sun Fire T2000 Server Installation Guide April 2006...
Page 14: ...xiv Sun Fire T2000 Server Installation Guide April 2006...
Page 16: ...xvi Sun Fire T2000 Server Installation Guide April 2006...
Page 54: ...34 Sun Fire T2000 Server Installation Guide April 2006...
Page 70: ...50 Sun Fire T2000 Server Installation Guide April 2006...
Page 80: ...60 Sun Fire T2000 Server Installation Guide April 2006...