Sun Microsystems Sun Fire E20K Installation Manual Download Page 2

Preparing the Sun Fire Systems for the System
Controller CPU Board Installation

Caution –

Be sure you are properly grounded before you begin the

hardware removal and installation. There are four ground points on
the system cabinet, two at the front top left and top right, and two at
the rear top left and top right.

Caution –

The Sun Fire systems do not support the Netra CP2140

CompactPCI as a hot-swappable component.

The system controller CPU board, Netra CP2140 CompactPCI, is not a hot-
swappable component. Damage can occur to the board if all power-down
procedures are not followed.

Caution –

Before removing the system controller CPU board from

the system, the green activation LED must be off and the amber or
blue removal OK LED must be on.

1. Power off and remove the System Control (SC) board as defined in the

system service manual for your system.

2. Remove the SC and the system controller CPU board as defined in the

system service manual for your system.