Appendix B
Brocade Communications Systems Switch Troubleshooting
99
Removing Power
Caution –
Error messages are stored in RAM and are lost when power is removed
from the switch. Capture and view the error log output and note any error messages
before removing power.
Status and Activity Indicators
Front Panel LED Port Indicators
See the Brocade Silkworm Hardware Reference Manual for further details.
Front Panel LEDs
Definition
No light showing
No light or signal carrier (no module, no cable) for
media interface LEDs
Steady yellow
Receiving light or signal, but not yet online
Slow
1
yellow
Disabled (result of diagnostics or portDisable
command). Flashes every two seconds.
Fast
2
yellow
Error, fault with port. Flashes every 1/2 second.
Steady green
Online (connected with device)
Slow
1
green
Online, but segmented (loopback cable or
incompatible switch) flashes every two seconds.
Fast
2
green
Internal loopback (diagnostics). Flashes every 1/2
second.
Flickering green
Online and frames flowing through port.
1
Slow —2 seconds interval
2
Fast — 1/2 second interval
Summary of Contents for StorEdge
Page 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Page 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...