Tape Drive Problems
describes the corrective action for problems with the tape drives.
A move command failed.
Check the source and destination elements. The source
element should hold the cartridge to be moved; the
destination element should be empty. Be sure the gripper is
empty and all actuators are free of obstruction. Also, be sure
the library is on-line and the Stop button is released. Retry
the command.
A flash memory error is
reported.
Contact a field service engineer.
A maximum temperature
exceeded warning appears.
Turn off the library and allow it to cool down. Lower the
room temperature, if possible, and increase ventilation
around the library. (If the operating temperature is too high,
the library automatically shuts down until the temperature
drops.)
TABLE 6-5
Tape Drive Problems
Problem
Corrective Action
The library is unable to
communicate with a
drive.
This is indicated by a Drive Communication Time-out error.
Contact a field service engineer.
The tape drive does not
eject a cartridge.
Reset the library and retry the unload command. If the tape still
does not unload, stop the library, open the front door, and
manually unload and eject the cartridge.
A drive handle error
occurs.
Contact a field service engineer.
TABLE 6-4
Operating Problems (Continued)
Problem
Corrective Action
Summary of Contents for StorEdge L1000
Page 16: ...xvi Sun StorEdge L1000 User s Guide May 1998 ...
Page 18: ...xviii Sun StorEdge L1000 User s Guide May 1998 ...
Page 58: ...36 Sun StorEdge L1000 User s Guide May 1998 ...
Page 72: ...50 Sun StorEdge L1000 User s Guide May 1998 ...
Page 94: ...72 Sun StorEdge L1000 User s Guide May 1998 ...
Page 100: ...78 Sun StorEdge L1000 User s Guide May 1998 ...
Page 104: ...82 Sun StorEdge L1000 User s Guide May 1998 ...
Page 122: ...100 Sun StorEdge L1000 User s Guide May 1998 ...