20
Sun StorEdge 3000 Family Best Practices Manual • June 2004
6. Choose No to decline the controller reset.
7. Select channel 5.
8. Choose “channel Mode
→
RCCOM.”
9. Choose Yes to confirm.
10. Choose No to decline the controller reset.
11. Select channel 2.
12. Choose “channel Mode
→
drive.”
13. Choose Yes to confirm.
14. Choose No to decline the controller reset.
15. Select channel 3.
16. Choose “channel Mode
→
drive.”
17. Choose Yes to confirm.
18. Choose Yes to reset the controller.
Cautions
Caution –
The UNIX and Solaris
format
and Solaris
probe-scsi-all
commands
do not display all mapped LUNs if there is not a partition or logical drive mapped to
LUN 0.
Caution –
Do not use both in-band and out-of-band connections at the same time to
manage the array. Otherwise conflicts between multiple operations might occur.
Caution –
Suspend all I/O activities and unmount filesystems before issuing
download, reset, or shutdown commands.
Caution –
Do not connect HBAs of different speeds to the same FC channel.
Otherwise data corruption might occur.