Chapter 2
Installing Servers and Back-End Storage
45
4. Insert the hinged plastic connector at the left side of the CMA fully into the CMA
rail extension (
).
The plastic tab on the CMA rail extension locks the hinged plastic connector in place.
FIGURE 2-24
Mounting the Left Side of the Slide Rail
▼
To Verify the Operation of the Slide Rails and the CMA
Tip –
Two people are needed for this procedure: one to move the server in and out
of the rack and one to observe the cables and CMA.
1. For a cabinet or a free-standing rack, deploy the anti-tilt bar.
2. Unlock the slide lock buttons (
) at the right and left sides of the server
chassis, and slowly pull the server out of the rack until the slide rails reach their
stops.