2-20
SPARCcenter 2000 System Board Manual—October 1994
2
3. Use the ejector/injector levers to seat the board.
Simultaneously, swing both ejector/injector levers into the locked position.
Do not press on board to seat it — doing so will damage the connector pins.
4. Install two screws to secure the board to the card cage.
5. Connect any applicable interface cables to the system board backpanel.
2.10 Replacing the Rear Screen
1. Place the bottom of the panel on flanges near the bottom of the cabinet.
Refer back to Figure 2-1.
2. Tilt the rear screen against the frame and install two screws to secure the
screen in place.
2.11 Restarting the System
To verify that the hardware has been installed properly, run the POST program.
1. Turn on power to the monitor.
If the system lacks a monitor, connect an TTY terminal to serial port A on
the system master board and configure the terminal software. Refer to the
instruction manual shipped with the terminal for configuration instructions.
The most commonly-used set-up is:
•
9600 bps
•
1 stop bit
•
8 data bits
•
Parity off
•
Full duplex
Refer to the instruction manual shipped with the terminal for configuration
instructions.
Note – Parameters listed may differ from customer site settings. See the s
et-
defaults
&
printenv
commands in the manual, OpenBoot Command Reference.
2. Turn the server key switch to the On position to run POST diagnostics.
Watch the diagnostics display for error messages. POST should finish in
approximately 60 seconds.