SPARCclassic/SPARCclassic X/SPARCstation LX Service Manual • November 1993
2.5
Power-On Self-Test
For more information about the POST, see Chapter 3 “Power-On Self-Test (POST).”
2.6
Selected On-Board Tests
For information about how to run the On-Board Diagnostics, see Appendix C “On-
Board Diagnostics.”
TABLE 2-4
lists specific on-board diagnostic tests for
SPARCclassic and SPARCstation LX systems.
TABLE 2-4
On-Board Diagnostics
Test
Description and Requirements
test floppy
Tests the floppy drive’s ability to respond to commands. Requires a formatted diskette in
the drive.
test screen
Tests the system video graphics hardware and monitor. The
diag-switch?
NVRAM
parameter must be set to True for the test to run.
test scsi
Tests the SCSI logic on the main logic board. The
diag-switch?
NVRAM parameter
must be set to True for the test to run.
test net-aui
Performs internal and external loopback tests on the AUI (thick) Ethernet interface. A
cable must be connected to the system AUI Ethernet port and to an Ethernet tap, or the
test will fail the external loopback phase.
test net-tpe
Performs internal and external loopback tests on the twisted-pair Ethernet (TPE)
interface. A cable must be connected to the system TPE port and to a TPE hub, or the test
will fail the external loopback phase. If the
tpe-link-test?
parameter is
False
(disabled), the external loopback test will appear to pass even if a cable is not connected.
test net
Performs internal and external loopback tests on the auto-selected system Ethernet
interface. A cable must be attached to the system and to an Ethernet tap or hub, or the
external loopback test will fail.
test disk
test disk0
test disk1
test disk2
test disk
Tests internal or external SCSI disks that have a self-diagnostic program contained in the
drive controller. The drive must be spinning before this test is executed or the test will
fail. Enter a
boot
<disk alias> command to cause the drive to spin up. (
disk0
= SCSI
target 0,
disk1
= SCSI target 1,
disk2
= SCSI target 2,
disk and disk3
= SCSI target
3.)
test cdrom
Performs a diagnostic self-test on the CD-ROM drive. The CD-ROM must be set to SCSI
target 6 and have a CD inserted or the test will fail.
Summary of Contents for SPARC classic X
Page 28: ...1 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Page 48: ...3 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Page 58: ...4 10 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Page 68: ...6 6 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Page 114: ...9 24 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...
Page 168: ...A 4 SPARCclassic SPARCclassic X SPARCstation LX Service Manual November 1993 ...