Netra t1 User and Administration Guide • June 2000
Resetting the System
To reset the system, type the following at the
lom>
prompt:
Checking the Current Status of all Components
Monitored by the LOM
To see the current status of all the components monitored by the LOM, type the
following at the
lom>
prompt:
shows some sample output from the
environment
command: the Fault
LED is ON (because Fan 3 is running too slowly). All the Alarms are OFF. Fan 3 is
faulty, and one of the DC inputs (in this case, input A) to the Power Supply Unit has
failed.
FIGURE 9-1
The
environment
Command Showing Fan 3 and DC Input Supply Faults
Note –
If the fans or PSU fail on your Netra t1, please contact your local Sun
Enterprise Services representative.
lom> reset
lom> environment
lom>environmnet
Fault ON
Alarm 1 OFF
Alarm 2 OFF
Alarm 3 OFF
Fans:
1 OK speed 86%
2 OK speed 89%
3 FAULT speed 15%
PSUs:
1 In A failed
lom>
SysAdmin.book Page 80 Friday, March 30, 2001 2:38 PM