Netra 240 Server Service Manual
• June
2004
Serial Ports
The server has two serial ports, labeled SERIAL MGT and 10101.
lists the
default serial connection settings for both serial ports.
Serial Management Port
The serial management connector (labeled SERIAL MGT) is an RJ-45 connector that
can be accessed from the back panel. This port is the default connection to the
system, and you should use this port
only
for server management.
Caution –
You must use a shielded Ethernet cable to maintain your server’s NEBS
compliance. The cable’s shield must be grounded at both ends.
shows the pin numbering of the serial management port, and
describes the pin signals.
TABLE
B-4
Default Serial Connection Settings
Parameter
Setting
Connector
SERIAL MGT or 10101
Rate
9600 baud
Parity
None
Stop bits
1
Data bits
8