Sun Datacenter Switch 3456 Installation Guide • December 2008
Inspecting Fabric Cards
Inspect the fabric cards to see if they are ready for installation.
▼
To Inspect the Fabric Card iTRAC Connectors
The iTRAC connectors on fabric cards are the receptacles for the midplane connector
pins. These connectors are checked just as meticulously as the midplane connector
pins. However, you must verify that no connectors are damaged and no holes are
blocked.
You need the following tools:
■
Bright flashlight
■
Magnifying glass or loupe
■
Dental type metal pick
1. Unwrap the fabric card from its antistatic packaging.
2. Place the fabric card on a work surface with the iTRAC connectors facing you.
3. Using the flashlight positioned to the side and above you, look at the holes of
the left-end connector.
Look at the holes straight on. See
FIGURE 8-1
Inspecting Fabric Card Connectors