Status LEDs
User Guide—Sun Cobalt LX50 Server
6-3
Status LEDs
Front-Panel System Status LED
The front-panel system status LED is located as shown in Figure 81.
Figure 81.
Location of Front-Panel System Status LED
The front-panel system status LED has the states indicated in Table 10.
Critical Condition
A critical condition or non-recoverable threshold crossing is associated with the following events:
•
Temperature, voltage, or fan critical threshold crossing.
•
Power subsystem failure. The Baseboard
1
Management Controller (BMC) asserts this failure whenever it detects
a power control fault (for example, the BMC detects that the system power is remaining on even though the BMC
has deasserted the signal to turn off power to the system).
•
The system is unable to power up due to incorrectly installed processor(s), or processor incompatibility.
•
A satellite controller such as the HSC, or another IMPI-capable device, such as an add-in server management
PCI card, sends a critical or non-recoverable state, via the Set Fault Indication command to the BMC.
•
Critical Event Logging errors, including System Memory Uncorrectable ECC error and Fatal/Uncorrectable Bus
errors, such as PCI SERR and PERR.
Table 10.
System Status LED States
System Status LED State
System Condition
CONTINUOUS GREEN
Indicates the system is operating normally.
BLINKING GREEN
Indicates the system is operating in a degraded condition.
BLINKING AMBER
Indicates the system is in a non-critical condition.
CONTINUOUS AMBER
Indicates the system is in a critical or non-recoverable condition.
NO LIGHT
Indicates POST/system stop.
1. Baseboard refers to the server Main Board.
OM11670A
System Status LED
Summary of Contents for Cobalt LX50
Page 1: ...Sun Cobalt LX50 Server User Guide...
Page 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Page 14: ...xiv User Guide Sun Cobalt LX50 Server...
Page 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Page 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Page 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Page 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...