Symptom Cause Remedial Action
Prevention
Fan Noisy
(Cont'd’)
(Electric
and AC/DC)
Fan Not
Working
(Electric
and AC/DC)
Liquid
Buildup/
Lack of
Evaporat-
ion
Overflow-
ing Liquid
Fan damaged in
shipping, or bearing
are beginning to
wear if it is rattling.
Debris in fan or
Mechanical Failure.
Increased usage.
Failure of heating
system (Electric and
AC/DC)
Mineral salts may
have accumulated
in the evaporation
chamber over a few
years, reducing
evaporation rates.
Overflow drain not
hooked up
Unit tipped forward
3. If it is a vibration noise, you may need to tie
down the top of the stack with guide wires
and bracket the pipe that runs up the side of
the structure.
Have your serial number ready and call Sun-Mar
The amount of liquid varies substantially between
installations. The overflow drain needs to be
installed on all Centrex 2000 AF models as you
will have overflow in DC mode and with heavy use
on AC mode.
Check “heating not working”.
To get rid of these, fill the evaporation chamber
with very hot water. Leave overnight.
Drain all Liquid through the overflow drain by tip-
ping the unit up (make sure overflow is hooked
up first)
Connect overflow safety drain (See also increased
usage above)
Check and ensure that the unit is level or tilting
slightly towards the left by placing a 6mm -12mm
shim piece under the right side of the unit.
The fan is a continuously moving
part which will eventually have to be
changed. Do Not turn on and off
daily.
Install the safety drain. If the unit is
being used in DC mode there will be
very little evaporation.
Rake evaporating chamber vigor-
ously at spring startups for cottage
use, and once every other month for
residential use.