EV40 User’s Manual
WIRING INSTRUCTIONS (Hardwired)
Route the EV40 conduit to a nearby service panel or junction box. Use the included 1/2” trade
sized watertight fitting and sealing washer to provide a moisture-resistant seal with the service
panel or junction box. If necessary, drill a 7/8” diameter hole to accommodate the liquid tight
fitting.
Figure 8. Wiring the EV40 in a junction box
Page 14
Note:
Before connecting the EV40 service
conductors, please carefully read the section of
the manual titled ‘Service Connections’ on page
6. If you are unsure of the type of power provided
at the service panel, please consult with you local
utility or call your service representative for
assistance.
Note:
The three EV40 service conductors use
standard 10AWG, 75ºC copper wire. The
insulation of each conductor is colour coded for
standard 240VAC installation.
Green: Ground
Black: Line 1 (120VAC to Ground)
Red:
Line 2 (120VAC to Ground)
Les trois conducteurs service la EV40 utilisent
multibrins 10AWG, 75ºC fil de cuivre. L'isolation
de chaque conducteur est un codé couleur pour
une installation standard de 240VAC:
Vert: Mise a la Terre
Noir: Ligne 1 (120 VAC à Mise à la terre)
Rouge: Ligne 2 (120VAC à Mise à la terre)