All scales come complete with plastic cover and base, a large LCD display, 
which is easy to read. 
The water-resistant keyboard has 4 easy to use function keys: HOLD, 
UNIT, ON/ZERO/OFF,  TARE. 
With the standard AC adaptor included and rechargeable batteries, the 
scales can be used in a fixed location or as a portable scale. 

                                        

                                                           

 

Power 

   

Power can be supplied by mains adaptor and delivering a regulated 
switching adaptor. (Input: 120V, output: 15V 300mA) Using batteries inside 
of scale’s head (rechargeable battery 7.2V 1200mAH).   

 

SPECIFICATIONS 

Model #                     S6600               

 

Maximum Capacity 

660 lbs. / 300 kg   

Graduation 

0.2 lb / 0.1 kg 

Resolution 

1: 3000 

Tare Range 

Full range 

Repeatability (STD Dev) 

+/- 1d 

Linearity ± 

+/- 2d 

Units of Measure 

Kg/lb/oz 

Stabilisation Time 

1-2 sec. 

Operating Temperature 

5°C – 35°C or 13 F - 95°F 

Power supply 

Rechargeable batteries or AC adaptor 

Indicator display 

1.5” LCD digital display 

Dimensions (w x d x h) 

15.5x12.5x3.3 inch 

Gross Weight 

7.7 lb / 3.5 Kg   

 

 

2

 

OPERATOR’S INSTRUCTIONS 

Key description 

 

Tare

             - Set the display to zero by storing the 

current weight in the tare memory 

    On / Zero / Off

    - Turns the scale on, zero or off, 

Units 

 

 

  - Select kilograms, pounds or ounces 

    

Hold      

   

  - Temporarily memory the weight. 

Place an item to be weighed on the platform. Press 
HOLD key, the arrow of the left bottom will blink. 
The display shows the measured weight. 

                        After removing the item, the display still shows the 

weight. 

Press HOLD or TARE button to disable HOLD 
function. 

Turn the scale on using the 

On/Zero/Off

 key.  After the display is at 

zero, place an item to be weighed on the platform.  The display will 
show the weight.  The unit will be shown in kilograms unless the user 
has selected either pounds or ounces previously. 

If an empty container is used the weight can be ignored by zeroing the 
display.  To zero the display press the 

TARE

 key.  Then when material 

is placed in the container only the weight of the material will be shown. 

 

D I S P L A Y   S Y M B O L S  

Symbol 

Description 

è¡ç

  

scale in auto zero range  (indication = accurate zero) 

¡

 

result is stable   

kg , lb or oz 

scale in weighing mode 

Lo-bAt 

Battery is weak, after 5 minutes the scale will turn off   

 

Show the Net Weight is being display (NW) or the Gross   

Weight is displayed (GW) 

 