background image

 

o

 

Air the room in which the appliance is located for several minutes, and 

o

 

Contact the Service Department for advice. 

• 

The more coolant there is in an appliance, the larger the room in which it should be installed. In the 
event of a leakage, if the appliance is in a small room, there is the danger of combustible gases 
building up. For every ounce of coolant, at least 325 cubic feet of room space is required. The amount 
of coolant in the appliance is stated on the data plate inside the appliance. It is hazardous for anyone 
other than an Authorized Service Person to carry out servicing or repairs to this appliance. 

• 

Take serious care when handling, moving, and using the appliance to avoid either damaging the 
refrigerant tubing or increasing the risk of a leak. 

• 

Replacing component parts and servicing shall be done by factory-authorized service personnel so as 
to minimize the risk of possible ignition due to incorrect parts or improper service. 

 

FOLLOW WARNING CALLOUTS BELOW ONLY WHEN APPLICABLE TO YOUR MODEL 

• 

Use two or more people to move and install appliance. Failure to do so can result in back or other 
injury. 

• 

To ensure proper ventilation for your appliance, the front of the appliance must be completely 
unobstructed. Choose a well-ventilated area with temperatures above 50°F (10°C) and below 100°F 
(38°C). 

• 

The appliance should not be located next to ovens, grills or other sources of high heat. 

• 

The appliance must be installed with all electrical, water and drain connections in accordance with 
state and local codes. A standard electrical supply (115 V AC only, 60 Hz), properly grounded in 
accordance with the National Electrical Code and local codes and ordinances, is required. 

• 

Do not kink or pinch the power supply cord of the appliance. 

• 

The size of the fuse (or circuit breaker) should be 15 amperes. 

• 

It is important that the appliance be leveled in order to work properly. You may need to make several 
adjustments to level it. 

• 

All installations must be in accordance with local plumbing code requirements. 

• 

Make certain that the pipes are not pinched, kinked or damaged during installation. 

• 

Check for leaks after connection. 

• 

Never allow children to operate, play with or crawl inside the appliance. 

• 

Do not use solvent-based cleaning agents or abrasives on the interior. These cleaners may damage 
or discolor the interior. 

• 

Use this appliance only for its intended purpose as described in this User Manual. 

• 

Keep fingers out of the 

“pinch point” areas. Clearances between the drawers and cabinet are 

necessarily small. Be careful closing drawers when children are in the area. 

 

                   

Risk of child entrapment! 

Child entrapment and suffocation are not problems of the past. Junked or abandoned appliances are 
still dangerous, even if they will “just sit for a few days”. 

 

Before discarding your old appliance:  

• 

Take off the doors 

• 

Leave the shelves in place so that children may not easily climb inside. 

 
 
 

 

- SAVE THESE INSTRUCTIONS - 

 
 

Summary of Contents for ADRD18

Page 1: ...2DADA LX182DOS User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Write Model and Serial Numbers here Model No Serial No Felix Storch Inc An ISO 9001 2015 regist...

Page 2: ...n 7 Installation of the Handle 8 Panel Ready Installation 8 9 Operating your Appliance 9 11 Control Panel 9 ON OFF Power Mute 9 Setting the Temperature 9 Temperature Alarm Function 9 10 Smart Control...

Page 3: ...an adapter and do not use an extension cord Replace all panels before operating It is recommended that a separate circuit serving only your appliance be provided Use receptacles that cannot be turned...

Page 4: ...next to ovens grills or other sources of high heat The appliance must be installed with all electrical water and drain connections in accordance with state and local codes A standard electrical supply...

Page 5: ...lifornia This equipment is prohibited from use in California with any refrigerants on the List of Prohibited Substances for that specific end use in accordance with California Code of Regulations titl...

Page 6: ...exclusive properly grounded wall outlet NOTE When the product is installed there should be a small ventilation gap between the top of the appliance and the underside of any fitting above 6mm or 1 4 E...

Page 7: ...appliance However if you must use an extension cord it is absolutely necessary that it be a UL CUL Listed 3 wire grounding type appliance extension cord having a grounding type plug and outlet and th...

Page 8: ...ck into its groove Panel Ready Installation The appliance is designed to be panel ready To install a custom panel on the front of the drawers of your appliance follow the steps below 1 Open the drawer...

Page 9: ...xtreme cold or hot conditions may cause interior temperatures to fluctuate Connect power cord to a properly grounded outlet This appliance is equipped with Memory IC should there be a power interrupti...

Page 10: ...r LL from time to time If it occurs frequently or lasts for a long time you can restart the appliance by unplugging it then re plugging after 5 minutes If the problem occurs again after restarting ple...

Page 11: ...cabinet powers off it will not automatically exit Sabbath mode and it will keep Sabbath mode when it powers on again The Sabbath Mode will automatically turn off after 96 hours Defrosting The applianc...

Page 12: ...ower Failure Most power failures are corrected within a few hours If your power is going to be off for a longer period of time you need to take the proper steps to protect your contents Transporting Y...

Page 13: ...ppliance in a cooler place Leave the appliance to work for a while until the set temperature has been reached The light does not work Appliance is not connected to a power supply Tripped circuit break...

Page 14: ...stallation installation not in accordance with electrical or plumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for appliances operated outside the U...

Reviews: