3.  Remove the plastic insert on the opposite side of the fridge and door. Now fix the top door 

bracket  to  this  side  using  the  screws  that  were  previously  removed.  Replace  the  plastic 
hinge cover. 

 

4.  Remove the adjustable foot at the bottom of the fridge and set aside. 

5.  Unscrew the two screws holding the bottom door hinge and carefully move it across to the 

opposite  side.  Before fixing  it  into  position, fit the  door  to  the  top  and  bottom  hinge  (care 
must  be  taken  as  the  door  will  be  loose).  Once  this  has  been  completed,  screw  in  the 
adjustable foot to the opposite side of the fridge. 

 

Check  that  the  door  opens  and  shuts  correctly  after  you  have  completed  the  door  reversal 
process. 

The appliance must now be upright for a minimum of 3 hours before turning it on 

Preparation 

a.  Electrical  connection:  The  cooler  requires  a  three-hole,  well-grounded  socket  with  fuse. 

Never ground the cooler through a gas pipe, tap water pipe or the grounded wire of single-
phase  power  supply.  The  power  supply  should  be  110  to120  VAC  /  60Hz.  It  requires  a 
voltage  stabilizer  of  over  500VA  if  the  power  supply  is  out  of  this  range.  Never  share  the 
same circuit with other appliances.     

b. Operation test: Connect the cooler to power supply. The fan and compressor will run. The 

LED will light by turning on the switch fixed on the panel inside cabinet. In 30 minutes, the 
temperature inside the cabinet should have cooled down, indicating normal operation

 

Summary of Contents for SCR114L

Page 1: ...ANUAL To ensure safe operation please read this instruction manual thoroughly before use FELIX STORCH INC Summit Appliance Division ISO 9001 2015 registered 770 Garrison Avenue Bronx New York 10474 ww...

Page 2: ...Door Swing 4 5 Preparation 5 Safety Precautions 6 Storage of Articles 6 Temperature Adjustment 6 Defrosting 6 Cleaning Your Beverage Center 6 Maintenance 7 Caution 7 Normal Phenomena 7 Warnings 7 Dis...

Page 3: ...in back or other injury To ensure proper ventilation for your appliance the front of the unit must be completely unobstructed Choose a well ventilated area with temperatures above 61 F 16 C and below...

Page 4: ...is stated on the data plate on the back of the appliance It is hazardous for anyone other than an Authorized Service Person to carry out servicing or repairs Take serious care when handling moving an...

Page 5: ...cooler in a location where water can reach it or with unusually high humidity f This appliance is intended for use indoors such as in shopping centers restaurants etc Reversing the Door Swing This ap...

Page 6: ...and shuts correctly after you have completed the door reversal process The appliance must now be upright for a minimum of 3 hours before turning it on Preparation a Electrical connection The cooler re...

Page 7: ...splay of non potentially hazardous bottled or canned products only Temperature Adjustment Setting Off not operating Setting MIN lowest setting warmest internal temperature Setting MAX highest setting...

Page 8: ...e may be condensation on the door it can be dried with a cloth WARNINGS a Keep ventilation openings clear of obstruction b Do not use mechanical devices or other means to accelerate the defrosting pro...

Page 9: ...SCLOSURE For products manufactured after January 1 2019 Retail food refrigeration equipment manufactured after January 1 2019 designed to store and display chilled goods for commercial sale and that u...

Page 10: ...aporator Refrigeration system is at fault leakage or blocked Call for service There is frost or ice on the walls of the inner cabinet and internal temperature is too low the compressor never stops run...

Page 11: ...10 NOTES...

Page 12: ...rts or repair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 The removal and reinstallation of...

Reviews: