REMEMBER,  during  the  winter  months,  this  switch  should  be  in  the  “ON” 

position to insure heating demand is satisfied.

The  POWER  switch  must  be  set  in  the  “MAX”  position  when  a 

2 – stage thermostat or outdoor thermostat is installed and used to control the 

electric elements of the second stage.

The “CONTINUOUS FAN” switch turns the  blower on to continuous “LOW” 

speed. This  feature  will  filter  the  air  and  provide  for  better  distribution  in  the 

building.

Manual Furnace Controls

FAULT INDICATORS

The two left hand element LEDS also serve as fault indicators.

Should the airflow be restricted by dirty air filters, these two LEDs will flash to 

indicated poor air flow. Simply turn off the furnace and replace the filter with one 

the same as the original equipment and restart the furnace. The fault condition 

should reset.

CIRCUIT BREAKER

The circuit breaker is located at the right hand side of the front control panel

In the event that the fan motor or external device failure, the circuit breaker may 

trip.

Only a licensed technician should investigate the fault condition.

Pushing in the white button will reset the breaker. If the button fails to remain 

depressed, the fault condition may still exist.

Contact your service technician.

Summary of Contents for ELECTRIC WARM AIR FURNACE

Page 1: ...nstaller and where required by law a licenced technician FOR SERVICE CALL INSTALLATION INFORMATION _________________ _________________ Installing Contractor Telephone Number _________________ _________________ Unit Model Number Unit Serial Number _________________ Date of Installation MANUFACTURED BY SUMMERAIRE MANUFACTURING ...

Page 2: ...e The blower starts at cooling speed and the A C condenser is activated After approximately 7 minutes of cooling operation the blower speed adjusts to the latent cooling mode to maximize dehumidification This cycle is cancelable at the dipswitch on the furnace controller if conventional high speed sensible only cooling is preferred The selection of the modulation or non modulating function must be...

Page 3: ...nt LEDS also serve as fault indicators Should the airflow be restricted by dirty air filters these two LEDs will flash to indicated poor air flow Simply turn off the furnace and replace the filter with one the same as the original equipment and restart the furnace The fault condition should reset CIRCUIT BREAKER The circuit breaker is located at the right hand side of the front control panel In th...

Page 4: ... than room temperature If unit does not start cut power and call a qualified service technician MOTOR LUBRICATION Do NOT lubricate the blower motor it is permanently lubricated AIR FILTER This furnace should never be operated without filters A DIRTYAIR FILTER CAUSES INEFFICIENCYAND HIGHER OPERATING COSTS Clean or replace filters each heating season Filter specifications for the air filter installe...

Page 5: ...5 Filter size 20 X 20 x 1 CSA or ULC Certified Approved Type Disposable Note Changing the type or size of filter used in your Summeraire furnace can seriously affect the operation of the furnace ...

Page 6: ...rio and which prove defective after inspection and testing by Summeraire Mfg Any labour involved in effecting repair or replacement including diagnostic labour is excluded from this Warranty Warranty of parts replaced under this warranty ONLY assume the remaining period of the Original Warranty LIMITATIONS 1 This warranty does not cover defects or damages on equipment without serial number or wher...

Page 7: ...arranty is subject to the equipment being serviced and maintained as outlined in the Installation and User Manuals on an annual basis Failure to do so may void this warranty 10 Summeraire Mfg shall not be responsible for any consequential damages caused by any defect in the product 11 This is the ONLY warranty made by Summeraire Mfg All other warranties conditions or guaranties expressed or implie...