10
3. Electric wiring diagram
a. For power supply: 230V 50Hz
b. For power supply: 400V 50Hz
Note: 1)
Must be hard wired, plug is not allowed.
2) The swimming pool heat pump must be earthed well.
4. References for protecting devices and cable specification
MODELE
108023
108024
108025
Breaker
Rated Current (A)
9
12
16.5
Rated Residual
Action Current (mA)
30
30
30
Fuse (A)
9
12
16.5
Power Cord (mm
2
)
3x1.5
3 x 2.5
3 x 2.5
Signal cable (mm
2
)
3×0.5
3×0.5
3×0.5
※
Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, wire diameter must be increased. The
signal cable can be extended to 50m maximum.
Fuse
Earthing
Power Supply
230V 50Hz
Swimming Pool Heat Pump Wiring Board
Power Cord
Breaker
Distribution Box (Customer prepare)
Fuse
Earthing
Power Supply
400V 50Hz
Swimming Pool Heat Pump Wiring Board
Power Cord
Breaker
Distribution Box (Customer prepare)