2
Perform an arc test
1.
Tap Arc test icon ( ).
2.
After “Arc Test Ready”
appears, tap Set icon
. An
arc test is started.
3.
When the splicer shows
“Good arc state”, prepare fiber
again to proceed to the
splicing process. *Fibers are
not spliced in the arc test.
3
Start splicing process / Start heating cycle
1.
Tap Set icon
to start
the splicing process.
2.
Fusion splicing is completed.
3
. Open the wind hood. A proof
test is automatically carried
out.
4.
Remove the fiber from the
splicer. Center the protection
sleeve over the splice and
load the fiber in the heat
shrink oven.
Sumitomo Electric Industries, Ltd. reserves the right to change the specification or design without
notice and may therefore not coincide with the contents of this quick reference guide. E&OE
For further detailed operating instructions and functions, please see Operation manual.
The Operation manual can be downloaded via
http://www.rim-plus.sei.co.jp/index.html
OME2024102-2/Ver.1.00
Heater progress bar
* Repeat fiber preparation and arc tests
until “Good arc state.” is displayed.
Heating in progress
Pre-heating
Cooling
Standby
Operating procedures
1
Splice Program setting
1.
Tap the Splice Program label
on the Settings panel.
2.
Select fiber category.
3.
Tap the Splice Program you
would like to use.
* Setup and change the Heater Program in the same procedures as described above.
* ”Quick” heater program only
*AS24G180*
5.
Tap Heater icon to start
the heating process.