SUMERAIN SANITARY GROUP WWW.SUMERAIN.COM
6.3
Done the finish wall and drill proper window for maintain if needs in the future.
6.4
Take off the escutcheon and the temperature limit ring from the valve assembly.
6.5
Turn on and adjust the cartridge to achieve desired shower water’s maximum temperature.
Anti-scald protection. It is important that the mixer valve is tested regularly to prevent the risk of scalding and guarantee user
safety. This can be carried out as follows: with the mixer blend temperature set at 38°C isolate the cold water supply. The outlet
flow rate will reduce to a safe level.
Recommended outlet temperatures
We recommend the following set maximum mixed water outlet temperatures for use in all premises:
111.2
°
F [44°C] - for bath fill but see notes below.
105.8
°
F[41°C] - for showers.
105.8
°
F[41°C ]- for washbasins.
100.4
°
F[38°C] - for bidets.
The mixed water temperatures must never exceed 114.8
°
F[46°C] at terminal fitting.