CA 461
Leakage Control Type ABS CA 461
Installation guide
Page 1: ...81907022A 12 2020 en www sulzer com 3 4 5 6 3 4 5 6 110 230VAC L1 N CA 461 CA 461 Leakage Control Type ABS CA 461 Installation guide ...
Page 2: ...lity To avoid conducted electrical noise follow best practices and manufacturer EMC compliance recommendations when installing frequency converters Use shielded cables and 50 cm separation between power and signal cables Ensure that the cables are also separated from each other in cabinets Input Leakage Power Supply Connect terminal 3 to ground or housing of the pump Output 3 4 5 6 110 230VAC L1 N...
Page 3: ...2 flexible core stripped length 8 mm Power consumption 2 W Max load output 250 VAC 3 Ampere Altitude Max 2000 MASL or 6562 ft AMSL Attention If the unit is used in a manner not described in this document the protection provided by the equipment may be impaired 2 2 Dimensions 2 3 Cleaning How to clean the unit Power off the unit and only outside front shall be cleaned by using a dry soft cloth A go...