10
4.7.2
Changing direction of rotation
The safety hints in the previous sections must be observed!
T
he direction of rotation should only be altered by a qualified person.
If the direction of rotation is incorrect then this is altered by changing over two phases of the power supply cable
in the control panel. The direction of rotation should then be rechecked.
NOTE
The direction of rotation measuring device monitors the direction of rotation of the
mains supply or that of an emergency generator.
4.8
Connection of the seal monitor
In order to integrate the seal monitor into a control panel supplied by the customer it is necessary to use an
ABS DI-module and connect this in accordance with the circuit diagrams below.
NOTE
DI-modules are available for the voltages 110V, 220V, 380V, and 440V. DI-modules
are not supplied as standard.
1022-00
1023-00
Figure 12: DI Module (connection of neon bulb)
Figure 13: DI Module with relay for individual signaling
ATTENTION
Maximum relay contact loading: 2 Ampere