ECO ARC 600
6-12
Revision 1/10/08
6.6
Electric arc cuts out, coarse particles in spray coat, spray wires
feeding, not melted
Indication
Cause
Remedy
Power supply
Rectifier, transformer, or
main relays
Only specialist staff is allo-
wed to work at electrical
appliances.
Check rectifier, transformer
and main relays.
Drain valve
Filter insert dirty
Change filter
(s. maintenance)
or
Atomizer gas pressure too
low
Regulate compressed air
Set pressure > 3,5 bar
Spray wire melts down irre-
gularly.
Voltage too low.
Check voltage and set cor-
rectly
Spray device
Nozzle system soiled
Check and clean nozzle
system
(s. maintenance)
Frequency
inverter
Push-gear
If frequency transformer is
out of use (approx. 2 years),
the condensers inside the
appliance have to be activa-
ted.
(see manual TOSHIBA
Chap. 2.6.2).
ON OFF ON
System OFF
Error Underload
System OFF
Error Underload
System OFF
Error
Undervoltage
ON OFF BLINKING
System OFF
Error Temp.