2: Description
ShopTek™ ST4, ST5, ST7, ST11, ST15 Three-phase 60 Hz User Manual
88292018-236 R00
20
Subject to EAR, ECCN EAR99 and related export control restrictions.
. Press the Down arrow
to display
additional information about the compressor. The upper
line will indicate the name of the temperature, pressure,
or other measurement. The lower line indicates the pres-
ent reading.
. When you continue beyond the sta-
tus information, the display will show a list of control set-
tings. There are customer and factory settings. The
upper line will indicate the name of the setting. The lower
line displays the present value.
and
. To change a
selected setting press
and an interface will display
where a password is needed. Use
and
to change
values of each digit. Use
to move to next digit. After
all digits of the password have been accepted, press
.
Upon acceptance of password, the setting can be modi-
fied. Use buttons as above to change values. Press
to
accept changes.
. If there is no keypad activity, the
display will return to normal view in about one minute. If
the Start
, Stop
or Return/Reset
buttons are
pressed, the display also returns to normal view. If any of
these occur, the setting will not be altered.
If there are any warnings or recommended service
instructions, these will be periodically displayed on the
normal view.
The list of displays may be navigated from either direc-
tion by using the Up
or Down
arrow keys.
The Emergency Stop button located near the controller
overrides all electronic functions to turn off the control
devices. The controller senses this and will display
E-
stop
. To reset, twist and pull out the Emergency Stop
button.
2.9
LED lights
The three LED lights indicate the general conditions of
the machine.
• The Power indicator
indicates power is
supplied to the controller.
• The Run mode indicator
indicates compres-
sor operation is enabled. It lights steadily if the
motor is running.
• The red Fault indicator
indicates that a
compressor fault has occurred and needs to be
repaired before further operation. The text dis-
play will indicate the cause of the fault.
TOTAL RUN TIME:
337H 20M
Figure 2-11: Total run time
LOAD PRESS:
0110PSI
Figure 2-12: Load pressure
S
S
PASSWORD ******
Figure 2-13: Password entry
Figure 2-14: Load pressure setting
LOAD PRESS:
0110PSI