Section 8
39
DEX HEATED REGENERATIVE DRYER
TECHNICAL DESCRIPTION
OF COMPONENTS
Basic devices used in the dryer system are described
in this section. For more detailed additional
information refer to the component bulletins included
in the rear of this manual.
8.1
ADSORBER
An adsorber is a pressure vessel filled with
desiccant. At each end of the vessel are perforated
stainless steel flow distributors and desiccant support
screens. The sole purpose of the support screen is to
retain the desiccant in the vessel and evenly
distribute the process and regeneration flows across
the area of the desiccant bed for optimum drying and
regeneration.
8.2
DESICCANT
For this drying application an Activated Alumina
desiccant is used
8.3
HEATER
The regeneration heater is installed external to the
desiccant beds in an insulated heater housing. It is a
immersion type that is removable from the housing.
The heating elements are made with an incoloy
sheath material. They are attached to the plug by
brazing to ensure a leak free pressure connection is
obtained. For regeneration of this dryer a heater is
provided. A type “K” thermocouple is attached to the
sheath of one element to provide “sheath over-
temperature” protection.
8.4
VALVES
Inlet valves are Piston type Bronze valves, dryers up
to 650 CFM and High performance Butterfly valves
for 800 CFM and up are used for tower switching
and are equipped with a Normally open pneumatic
actuator. Purge Exhaust valves are piston type (up
to 650 CFM) and high performance butterfly valve
800 CFM. Valves are equipped with Spring Load
Normally close actuator. (Note: in case of any power
failure the exhaust valves will be closed and inlet
valve will be open. Fail safe design)
8.5
ACTUATORS
Each valve is equipped with a actuator. Dry
instrument quality compressed air is used for pilot
actuation. A minimum air pressure of 60-80 psig is
required.
8.6
REGENERATION BLOWER
A regenerative centrifugal direct mounted motor is
used to provide the air for regeneration. The blower
is equipped with an inlet filter/silencer to eliminate
any air borne particles eing taken into the blower
impeller system.
8.7
PRESSURE GAUGE
The dryer system is fitted with pressure gauges and
Pressure snubber on each vessel solely for the
purpose of “local” pressure indication. Do not replace
pressure gauges with liquid filled type.
Amount
_____lbs per vessel
Density
48 lbs/ft cubed
Size
1/8” , 3/16” & 1/4” diameter
Electrical power
_____KW
Voltage
_____480 volt, 3 phase, 60Hz.
Heater Enclosure
Rating
_____NEMA 1 (indoor)
(outdoor enclosure optional)
Summary of Contents for DEX Series
Page 12: ...12 NOTES ...
Page 16: ...16 NOTES ...
Page 21: ...21 NOTES ...
Page 22: ...DEX HEATED REGENERATIVE DRYER SECTION 5 22 5 9 ID DEX 200 02250195 339 ...
Page 24: ...DEX HEATED REGENERATIVE DRYER SECTION 5 24 5 10 ID DEX 250 300 02250195 340 ...
Page 26: ...DEX HEATED REGENERATIVE DRYER SECTION 5 26 5 11 ID DEX 400 600 02250195 341 ...
Page 28: ...DEX HEATED REGENERATIVE DRYER SECTION 5 28 5 12 P I DEX 200 3500 02250195 360 ...
Page 32: ...DEX HEATED REGENERATIVE DRYER SECTION 5 32 5 14 ELECTRICAL SCHEMATIC 02250195 367 ...
Page 34: ...DEX HEATED REGENERATIVE DRYER SECTION 5 34 ...
Page 38: ...38 NOTES ...
Page 40: ...40 NOTES ...
Page 41: ...Section 9 41 DEX HEATED REGENERATIVE DRYER SPARE PARTS LIST ...
Page 45: ...Section 10 45 DEX HEATED REGENERATIVE DRYER COMPONENT BULLETINS ...
Page 46: ...46 NOTES ...
Page 47: ...NOTES 47 ...