Subject to EAR, ECCN EAR99 and related export control restrictions.
Do not mix different types of fluids.
Contamination of
compressor fluid with mineral oil or other fluids may lead
to operational problems such as foaming, filter plugging,
orifice or line plugging.
When ambient conditions exceed those noted or if condi-
tions warrant use of extended life lubricants contact Sul-
lair for recommendation.
3.6
Application guide
Sullair encourages the user to participate in a fluid analy-
sis program with the fluid suppliers. This could result in a
fluid change interval differing from that stated in the man-
ual. Contact your Sullair dealer for details.
WARNING
Maintenance of all other components is still rec-
ommended as indicated in the Operator’s Man-
ual.
NOTE
Flush system when switching lubricant brands.
Figure 3-1: Fluid fill location
1. Fluid fill port
2. Sight glass
3. Fluid drain valve
4. Separator/sump tank