background image

10

ENGLISH 

Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)

CIF  A28763647

+34 916774540

Congratulations on your purchase

Congratulations on your purchase of the latest in energy 

efficient ceiling fans.

Energy efficiency: 

SULION motors belong to the latest 

design technology in fans, saving up to 70% in energy 

consumption with DC motors.

Silent operation: 

Thanks to R&D advances in our motors, we 

have effectively reduced their operating noise in all models.

Comfort:

 DC motor fans include up to 6-speed remote 

control which provides superior comfort levels in their use. 

Safety precautions

Follow these instructions carefully to enjoy 

maximum safety in the installation and 

operation of this equipment.

The electrical installation of the ceiling fan must 

be carried out by an authorized electrician 

in order to be covered by our warranty. 

Please remember to require your installer to 

test all the fan functions before you leave. 

In case of any doubt from the installer, do not 

hesitate to contact us.

This device can be used by children aged 8 

years and above and people with reduced 

physical, sensory or mental abilities or lack 

of experience or knowledge, if they have 

been given appropriate supervision or training 

regarding the use of the device and they 

understand the dangers of its use. Children 

should not play with the device. The cleaning 

and maintenance of the device should not be 

carried out by children without supervision.

The fan must be installed in such a way that 

the blades are more than 2,3m above the 

ground. Make sure that there is a space of at 

least 30cm between the fan’s blades and any 

wall or other obstacle that they could hit. It is 

important to note that the greater the distance, 

the more efficient the air flow produced will 

be.

Any action performed for the electrical 

connection of the device, such as its cleaning, 

must be carried out after ensurin that the 

general power supply is disconnected, by 

removing the corresponding fuse or disarming 

the protective switch in order to ensure total 

isolation of the power supply. 

The system of attaching the fan bracket to the 

ceiling will depend on the type of ceiling where 

the installation is to be done. The decision 

on which attachment system to use and the 

quantity is the installer’s responsibility.

The fan must be installed at a location on 

the ceiling sch that the blades are at least 

2.3 m above the floor and 300 mm from any 

object or wall. The mounting bracket must be 

attached to a ceiling structure that is capable 

of supporting a minimum of 30 kg using the two 

screws provided. At least 30 mm of the length 

of the screws must be screwed into the bracket. 

When deciding where to mount the fan, be sure 

that there is at least 30 cm of space between the 

fan and any wall or other obstruction that the fan 

blades could collide with. The greater this distance, 

the more effective the air flow produced.After the 

fan is mounted, be sure that the blades are no less 

than 2.3 m above the ground

The ground wire of the fan must be connected to 

the earth network of the installation, to avoid any 

derivation that may put people in danger.

Do not connect the fan’s power supply to any 

dimmers, potentiometers, or light switches, as 

it will cause the fan to malfunction and/or will 

damage the motor. For the electrical connection it 

is necessary to incorporate a switch disconnector 

in accordance with the installation regulations, 

which ensures an omnipolar cut, directly 

connected to the power terminals and must 

have a contact separation at all its poles, which 

provides total disconnection under conditions of 

Category III overvoltage. The fan must be directly 

connected to a properly protected installation 

circuit (magnetothermal differential switch with 

the adequate size for the fan’s consumption and 

technical specifications). Only use the fan’s control 

to turn it on or stop it.

It is recommended not to use these types of fans 

along with gas installations simultaneously in the 

same room.

Do not insert anything that could hit the fan’s 

blades into its pathway while it is moving, as this 

could cause damage to people, can damage the 

blades, and can offset the balance of the unit, 

causing vibrations and wobbling.

 After installing the fan, ensure that all fastenings 

are secure and tightened in order to avoid any 

noise caused by loose elements.Due to the fan’s 

movement, certain fastenings may become loose. 

Check all fastenings twice per year at a minimum 

in order to ensure that they are sufficiently tight. If 

necessary, they must be retightened.

If the power cord is damaged, it must be replaced 

by the manufacturer, its after-sales service or 

similar qualified personnel in order to avoid any 

malfunction.

 Replaceable LED

 Replaceable driver

 Replaceable receiver and remote control

Do not throw away electrical products together 

with household waste. We ask you to recycle the 

packaging at the collection points provided for this 

purpose. Contact local authorities or your provider 

for recycling advice. Thank you for recycling at the 

<8

Kg

OFF

OFF

Summary of Contents for ROAD AQUA 1003864

Page 1: ...deos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 e...

Page 2: ...2 ESPA OL Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 3: ...3 ESPA OL www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es...

Page 4: ...98 EN T l chargez le guide de l utilisateur sur notre site Web sulion es ean 8426107054098 FR Baixe o guia do usu rio em nossa web sulion es ean 8426107054098 PT DE Laden Sie die Bedienungsanleitung i...

Page 5: ...amiento del suministro el ctrico Espa ol 05 English 11 Instalaci n del ventilador Fan installation 16 ndice Indice Index1 Componentes Parts Repuestos Spares Herramientas requeridas Required tools Enho...

Page 6: ...pueden y deben ser aportados por el usuario que cuida y disfruta de este ventilador La instalaci n debe de ser realizada por personal cualificado para realizar instalaciones el ctricas de acuerdo a l...

Page 7: ...o de espera W 0 5 Norma de medici n del valor de servicio EN 62879 2020 LED Potencia 18W Flujo 1800lm Temperatura de color 3000 4000 6000K RGB No Medici n datos luz 360 N de ciclos ON OFF 10000 N de h...

Page 8: ...y receptores de los ventiladores habr n quedad sincronizados Quite la corriente de los ventiladores mediante el interruptor o el autom tico y acto seguido vuelva a encenderlos este paso es el que cie...

Page 9: ...balancearse du rante su funcionamiento El balanceo de dos cent metros es totalmente aceptable y no sugiere ning n mal funciona miento ni originar su ca da si se mont siguiendo este ma nual de forma a...

Page 10: ...om any object or wall The mounting bracket must be attached to a ceiling structure that is capable of supporting a minimum of 30 kg using the two screws provided At least 30 mm of the length of the sc...

Page 11: ...of ON OFF cycles 10000 N of hours of lifespan 30000h Dimmable Yes Angle 165 CRI 80 This product have a light source of energy efficiency class F Fan Speed 6 Power W 20 RPM 200 Airflow m min 183 Airfl...

Page 12: ...een synchronized Turn off the fan s current using the switch or automatic and then turn it back on s this step is the one that closes the synchronization process It is not possible for a controller to...

Page 13: ...operation A wobble of 2 cm is perfectly acceptable and does not indi cate any malfunction nor will it cause the fan to fall as long as it was mounted to the ceiling correctly following the instruction...

Page 14: ...lle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 Instalaci n ventilador Fan installation 1 2 OFF NO INCLUIDOS NOT INCLUDED 1 2 3 02 03 05 0...

Page 15: ...15 www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es Green Yellow B la ck Brown Blue G re e n Y e llo w W h it e Click 3 1 2 08 06 07...

Page 16: ...16 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 2 1 3 4 5 3 3 10 09 ON ON...

Page 17: ...ORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60598 1 2015 A1 2018 EN 60598 2 1 1989 EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 80 2003 A1 2004...

Page 18: ...www sulion es...

Reviews: