Device technical spectifications

General

Nominal voltage and frequency

220-240V~AC 50/60Hz

Protection category

Clase I

Ingress protection

IP20

Work temperature

-5 

40ºC

Maximun ceiling slope on which it can be installed

  15º

Weight

6Kg

Power consumption in standby mode (W)

<0,5

Service value measurement standard

EN 62879:2020

Bulb

Bush

E27

Number of bushes

2

Wattage

Máx. 2x40W 

Maximum bulb size

60mm

B

82mm

Fan

Speed

6

Power (W)

28

RPM

230

Airflow (m³/min)

155

Airflow (m³/h)

9300

Max noise level (dB)

55

Service value SV ((m³ / min) / W)

5,53

Maximum air speed (m / sec)

2,20m/s

Installing a fan without a shaft, flush with the ceiling, can reduce airflow.

B

A

Summary of Contents for BALOO 2171456

Page 1: ...eos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 ema...

Page 2: ...2 ESPA OL Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 3: ...3 ESPA OL www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es...

Page 4: ...02 EN T l chargez le guide de l utilisateur sur notre site Web sulion es ean 8426107055002 FR Baixe o guia do usu rio em nossa web sulion es ean 8426107055002 PT DE Laden Sie die Bedienungsanleitung i...

Page 5: ...aislamiento del suministro el ctrico Espa ol 02 English 09 Instalaci n del ventilador Fan installation 13 ndice Indice Index1 Componentes Parts Repuestos Spares Herramientas requeridas Required tools...

Page 6: ...actores s lo pueden y deben ser aportados por el usuario que cuida y disfruta de este ventilador La instalaci n debe de ser realizada por personal cualificado para realizar instalaciones el ctricas de...

Page 7: ...r 15 Peso 6Kg Consumo de energ a en modo de espera W 0 5 Norma de medici n del valor de servicio EN 62879 2020 Bombilla Casquillo E27 N mero de casquillos 2 Potencia M x 2x40W Medida m x de bombilla A...

Page 8: ...egundos pulsar la tecla del control remoto durante 10 segundos continuados 2 Un sonido de tipo beep indica que la conexi n ha sido ejecutada y el equipo puede funcionar normalmente 3 Ahora control rem...

Page 9: ...do tal y como se explica a continuaci n 3 Encienda el ventilador en la velocidad m s alta para que se produzca mayor balanceo 4 Apague el ventilador Seleccione un aspa y coloque el clip ver figura en...

Page 10: ...es de techo tienden a balancearse du rante su funcionamiento El balanceo de dos cent metros es totalmente aceptable y no sugiere ning n mal funciona miento ni originar su ca da si se mont siguiendo es...

Page 11: ...loor and 300 mm from any object or wall The mounting bracket must be attached to a ceiling structure that is capable of supporting a minimum of 30 kg using the two screws provided At least 30 mm of th...

Page 12: ...ucts These factors can and must only be provided by the user who maintains and enjoys this fan Device technical spectifications General Nominal voltage and frequency 220 240V AC 50 60Hz Protection cat...

Page 13: ...ous seconds 2 A beep sound indicates that the connection has been executed and the equipment can function normally 3 Now transmitter and receiver of the fan s will have been synchronized Turn off the...

Page 14: ...to the highest speed so that the greatest amount of wobbling is produced 2 Turn off the fan Select a blade and place a clip on it see diagram halfway between the fastening and the far edge of the blad...

Page 15: ...operation A wobble of 2 cm is perfectly acceptable and does not indi cate any malfunction nor will it cause the fan to fall as long as it was mounted to the ceiling correctly following the instruction...

Page 16: ...Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 Instalaci n ventilador Fan installation OFF 1 70 2 3 NO INCLUIDOS NOT INCLUDED Green Yellow B la c k Brown Blue G re e n Y...

Page 17: ...17 www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es x3 1 2 3 4 5 1 2 1 2 3 1 2 3 10 11 13 09 08 14 12 OPTION 1...

Page 18: ...18 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 2 3 1 Click 1 2 17 18 16 15...

Page 19: ...19 www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es 1 2 2 3 4 1 2 21 22 11 12 20 19 16 ON ON OPTION 2...

Page 20: ...20 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 2 1 2 3 4 14 16 03 15 17 ON ON...

Page 21: ...ORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60598 1 2015 A1 2018 EN 60598 2 1 1989 EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 80 2003 A1 2004...

Page 22: ...22 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 23: ...23 www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es...

Page 24: ...www sulion es...

Reviews: