background image

3

2

ESP

AÑOL

ESP

AÑOL

Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)

 

 

www.sulion.es

CIF  A28763647

+34 916774540

ATC: 

916749481 - [email protected]  /  

SAT :

 916749483 - [email protected]

Summary of Contents for 2174792

Page 1: ...eos instrucciones y una guía de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 email info sulion es or with technical department at 916749483 email sat sulion es Before calling note of the reference name IMP located on the product sticker or next to the barcode on the box and descr...

Page 2: ...3 2 ESPAÑOL ESPAÑOL Calle Verano 51 Polígono Industrial Las Monjas 28850 Torrejón de Ardoz Madrid ESPAÑA www sulion es CIF A28763647 34 916774540 ATC 916749481 info sulion es SAT 916749483 sat sulion es ...

Page 3: ...ico del aparato así como para su limpieza debe ser solamente realizado tras asegurarse de que la alimentación eléctrica general de la instalación está desconectada pormediodeldesmontajedelcorrespondiente fusible o el desarmado del interruptor protector de la instalación para garantizar total aislamiento del suministro eléctrico Español 02 English 09 Instalación del ventilador Fan installation 13 Í...

Page 4: ...r a su instalador la prueba de todas las funciones del ventilador antes de irse Ante cualquier duda del instalador no duden en contactarnos Este aparato pueden utilizarlo niños con edad de 8 años y superior y personas con capacidades físicas sensoriales o mentales reducidas o falta de experiencia o conocimiento si se les ha dado la supervisión o formación apropiadas respecto al uso del aparato de ...

Page 5: ...ración o pérdida del brillo 4 No hay necesidad de aceitar el ventilador El motor tiene cojinetes de lubricación permanente Nota El hecho de no respetar estas instrucciones provoca la pérdida de la garantía del equipo Servicio de garantía La garantía del fabricante cubre fallos reales que puedan producirse pero no quejas menores como el ruido que ge nera el equipo pues todos los motores eléctricos ...

Page 6: ...he fan blades could collide with The greater this distance the more effective the air flow produced After the fan is mounted be sure that the blades are no less than 2 3 m above the ground The ground wire of the fan must be connected to the earth network of the installation to avoid any derivation that may put people in danger Do not connect the fan s power supply to any dimmers potentiometers or ...

Page 7: ...t in the device Warranty Manufactures guarantees the proper functioning of this equipment repairs or spare parts of the model owing to faulty manufacture during 3 years after the surrender date 8 years exclusively in the case of the fan motor Responsi bility will not be accepted however for damages or injury caused through misuse For any claims the sale ticket must be presented The company agrees ...

Page 8: ...CIF A28763647 34 916774540 ATC 916749481 info sulion es SAT 916749483 sat sulion es Instalación ventilador Fan installation 40 1 2 3 100 1 2 3 4 5 1 2 1 2 3 1 2 3 4 02 04 06 01 03 05 07 2 3 1 OFF NO INCLUIDOS NOT INCLUDED Gre en Ye llo w Bro wn Blu e Green Yellow Brow n Blue Click 2 1 11 12 13 14 08 09 10 ...

Page 9: ...IONdeclareunderourownresponsibilitythattheproductslistedbe lowhavebeenmanufacturedinaccordancewiththefollowingEuropean standards DECLARACIÓN DE CONFORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 80 2003 A1 2004 A2 2009 EN 62233 2008 Article 3 1b EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2...

Page 10: ...www sulion es ...

Reviews: