background image

13

ENGLISH 

 

 

www.sulion.es

ATC: 

916749481 - [email protected]  /  

SAT :

 916749483 - [email protected]

Remote control

Instructions for synchronizing the 

receiver and the remote control

The control is already factory-linked with its receive. 

Make sure all connections are correctly made.

Make sure that the remote control contains batteries.

Make sure that all switches (main and isolation) are on.

The control of this fan have two mode of synchronization, 

Universal mode and Unit mode:

- Unit Mode:

This type of synchronization allows you to control two or 

more nearby fans independently, each with its remote con-

trol.

Synchronization:

The control of this fan does not require synchronization 

with the receiver, the control is already factory-linked with 

its receiver

- Universal Mode:

This type of synchronization allows you to control one or 

more nearby fans with the same remote control.

Synchronization:

1.-Connect the power (wall switch) of the fan or fans that 

you want to control, and then just within the following

15 seconds, press the key   of the remote control for 10 

continuous seconds.

2.-A “beep” sound indicates that the connection has been 

executed and the equipment can function normally.

3.-Now, transmitter and receiver of the fan / s will have 

been synchronized. Turn off the fan / s current using the

switch or automatic and then turn it back on / s, this step 

is the one that closes the synchronization process.

It is not possible for a controller to forget a fan once it has 

been linked, if you want a fan to leave

to obey a command, another one must be linked to 

“overwrite it”.

Preparing for installation

Note: 

The estimated installation time is 120 minutes. This 

product can only be installed by a certified electrician Ca-

refully separate the fan’s parts, avoiding the use of cutters 

or blades that could scratch any part of it.

Remove the fan from the packaging carefully, avoiding the 

use of knives which could scratch any part of it.
Remove all the components. Place the motor on a cloth or 

wet surface so as not to damage its surface finish. Carefully 

handle the unit to make sure that its casing does not bend 

or get scratched.
The fan must be mounted on the floor or a large enough 

table to prevent any component from falling off.

Light color temperature change

You can change the color temperature of the light, turning 

off and on, with the wall switch, the remote control or in 

case of being an IoT fan from your terminal.

WARM

WARM

NEUTRAL

WARM

ON

ON

>20”

OFF

OFF

WARM

NEUTRAL

COLD

ON

ON

OFF

OFF

OFF

ON

Timer

Nature wind

Turn on/off

the fan
Change

color 

temperature

Turn on/off

the light

Speeds

Summer

/Winter

1

2H

4H

2

5

4

3

6

Yellow

White

Blue

Summary of Contents for 1694604

Page 1: ...eb www sulion es donde encontrar s un acceso a v deos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer cal...

Page 2: ...2 ESPA OL Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 3: ...3 ESPA OL www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es...

Page 4: ...09 EN T l chargez le guide de l utilisateur sur notre site Web sulion es ean 8426107054609 FR Baixe o guia do usu rio em nossa web sulion es ean 8426107054609 PT DE Laden Sie die Bedienungsanleitung i...

Page 5: ...del interruptor protector de la instalaci n para garantizar total aislamiento del suministro el ctrico Espa ol 05 English 11 Instalaci n del ventilador Fan installation 16 ndice Indice Index1 Herramie...

Page 6: ...actores s lo pueden y deben ser aportados por el usuario que cuida y disfruta de este ventilador La instalaci n debe de ser realizada por personal cualificado para realizar instalaciones el ctricas de...

Page 7: ...pera W 0 5 Norma de medici n del valor de servicio EN 62879 2020 LED Principal Potencia 36W Flujo 3300lm Temperatura de color 3000 4000 6000K RGB No Medici n datos luz Esfera 360 N de ciclos ON OFF 10...

Page 8: ...e 3 Ahora control remoto y receptores de los ventiladores habr n quedad sincronizados Quite la corriente de los ventiladores mediante el interruptor o el autom tico y acto seguido vuelva a encenderlos...

Page 9: ...te figura Si existen variaciones y el adecuado apriete de tornillos ha sido ya efectua do compruebe que la forma de las aspas es id ntica en todas ellas pues si alguna de ellas presenta una forma acus...

Page 10: ...res de techo tienden a balancearse du rante su funcionamiento El balanceo de dos cent metros es totalmente aceptable y no sugiere ning n mal funciona miento ni originar su ca da si se mont siguiendo e...

Page 11: ...loor and 300 mm from any object or wall The mounting bracket must be attached to a ceiling structure that is capable of supporting a minimum of 30 kg using the two screws provided At least 30 mm of th...

Page 12: ...N of hours of lifespan 30000h Dimmable No Angle 120 CRI 80 This product have a light source of energy efficiency class E Fan Speed 6 Power W 22 RPM 220 Airflow m min 172 Airflow m h 10300 Max noise le...

Page 13: ...will have been synchronized Turn off the fan s current using the switch or automatic and then turn it back on s this step is the one that closes the synchronization process It is not possible for a co...

Page 14: ...s exist and you have already correctly tightened the screws check that all blades have the same shape If any of them have a shape that is visibly different this may be causing an imbalance during fan...

Page 15: ...eir operation A wobble of 2 cm is perfectly acceptable and does not indi cate any malfunction nor will it cause the fan to fall as long as it was mounted to the ceiling correctly following the instruc...

Page 16: ...le Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 Instalaci n ventilador Fan installation 1 1 2 1 2 3 4 5 1 2 1 2 3 1 2 3 4 01 03 05 07 02 04...

Page 17: ...w sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es 2 3 1 1 2 70 NO INCLUIDOS NOT INCLUDED OFF Green Yellow B la c k Brown Blue G re e n Y e ll o w W h it e Click 1 2 09 12 14 15 10 1...

Page 18: ...18 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 1 2 3 4 16 17 19 18 ON ON...

Page 19: ...ORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60598 1 2015 A1 2018 EN 60598 2 1 1989 EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 80 2003 A1 2004...

Page 20: ...www sulion es...

Reviews: