background image

16

Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)

CIF  A28763647

+34 916774540

Instalación ventilador / Fan installation

1

1

2

1

2

3

4

5

1

2

1

2

3

1

2

3

4

01

03

05

07

02

04

06

08

Summary of Contents for 1694574

Page 1: ...web www sulion es donde encontrarás un acceso a vídeos instrucciones y una guía de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 email info sulion es or with technical department at 916749483 email sat sulion es Before calling note of the reference name IMP located on the product ...

Page 2: ...2 ESPAÑOL Calle Verano 51 Polígono Industrial Las Monjas 28850 Torrejón de Ardoz Madrid ESPAÑA CIF A28763647 34 916774540 ...

Page 3: ...3 ESPAÑOL www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es ...

Page 4: ...753 EN Téléchargez le guide de l utilisateur sur notre site Web sulion es ean 8426107054753 FR Baixe o guia do usuário em nossa web sulion es ean 8426107054753 PT DE Laden Sie die Bedienungsanleitung in unserem Web herunter sulion es ean 8426107054753 Scarichi il manuale nella sua lingua sul nostro sito web sulion es ean 8426107054753 IT ...

Page 5: ...del interruptor protector de la instalación para garantizar total aislamiento del suministro eléctrico Español 05 English 11 Instalación del ventilador Fan installation 16 Índice Indice Index1 Herramientas requeridas Required tools Enhorabuena por su compra Enhorabuena por adquirir lo último en ventiladores de techo Eficiencia energética Los motores SULION pertenecen a la última tecnología de dise...

Page 6: ...actores sólo pueden y deben ser aportados por el usuario que cuida y disfruta de este ventilador La instalación debe de ser realizada por personal cualificado para realizar instalaciones eléctricas de acuerdo a la norma vigente en el país de instalación Recuerde exigir a su instalador la prueba de todas las funciones del ventilador antes de irse Ante cualquier duda del instalador no duden en conta...

Page 7: ...pera W 0 5 Norma de medición del valor de servicio EN 62879 2020 LED Principal Potencia 24W Flujo 2400lm Temperatura de color 3000 4000 6000K RGB No Medición datos luz Esfera 360º Nº de ciclos ON OFF 10000 Nº de horas de vida 30000h Dimable No Ángulo 120º CRI 80 Este producto contiene una fuente luminosa de la clase de eficiencia energética E Ventilador Velocidades 6 Potencia máx W 9 RPM máx 220 F...

Page 8: ...e 3 Ahora control remoto y receptores de los ventiladores habrán quedad sincronizados Quite la corriente de los ventiladores mediante el interruptor o el automático y acto seguido vuelva a encenderlos este paso es el que cierra el proceso de sincronización Nota No es posible que un control remoto olvide un receptor es una vez ha sido vinculado si se quiere que un receptor deje de obedecer a un con...

Page 9: ...ente figura Si existen variaciones y el adecuado apriete de tornillos ha sido ya efectua do compruebe que la forma de las aspas es idéntica en todas ellas pues si alguna de ellas presenta una forma acusadamente diferente puede producir el des equilibrio al girar el ventilador Si tras los pasos anteriores el balanceo no ha sido resuelto es necesario aplicar el equilibrado dinámico con el kit su min...

Page 10: ...res de techo tienden a balancearse du rante su funcionamiento El balanceo de dos centímetros es totalmente aceptable y no sugiere ningún mal funciona miento ni originar su caída si se montó siguiendo este ma nual de forma adecuada al techo Este ventilador de techo dispone de un sistema de montaje totalmente seguro por medio de soportes de acero y esferas de unión para permi tir su giro y evitar tr...

Page 11: ...floor and 300 mm from any object or wall The mounting bracket must be attached to a ceiling structure that is capable of supporting a minimum of 30 kg using the two screws provided At least 30 mm of the length of the screws must be screwed into the bracket When deciding where to mount the fan be sure that there is at least 30 cm of space between the fan and any wall or other obstruction that the f...

Page 12: ...00 Nº of hours of lifespan 30000h Dimmable No Angle 120º CRI 80 This product have a light source of energy efficiency class E Fan Speed 6 Power W 9 RPM 220 Airflow m min 95 Airflow m h 5700 Max noise level dB 38 Service value SV m min W 10 5 Maximum air speed m sec 2 54m s purpose Contact local authorities or your provider for recycling advice Thank you for recycling at the collection points provi...

Page 13: ... will have been synchronized Turn off the fan s current using the switch or automatic and then turn it back on s this step is the one that closes the synchronization process It is not possible for a controller to forget a fan once it has been linked if you want a fan to leave to obey a command another one must be linked to overwrite it Preparing for installation Note The estimated installation tim...

Page 14: ...ns exist and you have already correctly tightened the screws check that all blades have the same shape If any of them have a shape that is visibly different this may be causing an imbalance during fan operation If you have completed the previous steps and the wob bling has not resolved you should apply dynamic balan cing with the kit provided as explained below 1 Turn the fan on to the highest spe...

Page 15: ...heir operation A wobble of 2 cm is perfectly acceptable and does not indi cate any malfunction nor will it cause the fan to fall as long as it was mounted to the ceiling correctly following the instructions in this manual This ceiling fan has a comple tely secure mounting system that uses steel brackets and connecting spheres to allow it to rotate and to prevent the transmission of vibrations to t...

Page 16: ...lle Verano 51 Polígono Industrial Las Monjas 28850 Torrejón de Ardoz Madrid ESPAÑA CIF A28763647 34 916774540 Instalación ventilador Fan installation 1 1 2 1 2 3 4 5 1 2 1 2 3 1 2 3 4 01 03 05 07 02 04 06 08 ...

Page 17: ...ww sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es 2 3 1 1 2 70 NO INCLUIDOS NOT INCLUDED OFF Green Yellow B la c k Brown Blue G re e n Y e ll o w W h it e Click 1 2 09 12 14 15 10 11 13 ...

Page 18: ...18 Calle Verano 51 Polígono Industrial Las Monjas 28850 Torrejón de Ardoz Madrid ESPAÑA CIF A28763647 34 916774540 1 2 3 4 16 17 19 18 ON ON ...

Page 19: ...FORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60598 1 2015 A1 2018 EN 60598 2 1 1989 EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 80 2003 A1 2004 A2 2009 EN 62233 2008 EN 62471 2008 EN 62493 2010 Article 3 1b EN 55014 1 2006 A1 2009 A2 2011 EN 55014 2 1997 A1 2001 A2 2008 EN 55015 2013 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 61547 2009 EN 301 ...

Page 20: ...www sulion es ...