Remote control

Instructions for synchronizing the 

receiver and the remote control

The control is already factory-linked with its receive. 

Make sure all connections are correctly made.

Make sure that the remote control contains batteries.

Make sure that all switches (main and isolation) are on.

The control of this fan have two mode of synchronization, 

Universal mode and Unit mode:

- Unit Mode:

This type of synchronization allows you to control two or 

more nearby fans independently, each with its remote con-

trol.

Synchronization:

The control of this fan does not require synchronization 

with the receiver, the control is already factory-linked with 

its receiver

- Universal Mode:

This type of synchronization allows you to control one or 

more nearby fans with the same remote control.

Synchronization:

1.-Connect the power (wall switch) of the fan or fans that 

you want to control, and then just within the following

15 seconds, press the key   of the remote control for 10 

continuous seconds.

2.-A “beep” sound indicates that the connection has been 

executed and the equipment can function normally.

3.-Now, transmitter and receiver of the fan / s will have 

been synchronized. Turn off the fan / s current using the

switch or automatic and then turn it back on / s, this step 

is the one that closes the synchronization process.

It is not possible for a controller to forget a fan once it has 

been linked, if you want a fan to leave

to obey a command, another one must be linked to 

“overwrite it”.

Preparing for installation

Note: 

The estimated installation time is 120 minutes. This 

product can only be installed by a certified electrician Ca-

refully separate the fan’s parts, avoiding the use of cutters 

or blades that could scratch any part of it.

Remove the fan from the packaging carefully, avoiding the 

use of knives which could scratch any part of it.
Remove all the components. Place the motor on a cloth or 

wet surface so as not to damage its surface finish. Carefully 

handle the unit to make sure that its casing does not bend 

or get scratched.
The fan must be mounted on the floor or a large enough 

table to prevent any component from falling off.

Timer

Viento natural

Turn on/off

the fan

Turn on/off

the light

Speeds

Change

color

temperature

Change

light

intensity

Summer /

Winter

Summary of Contents for 1694314

Page 1: ...eos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your retailer call our customer service department at 916749481 ema...

Page 2: ...2 ESPA OL Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 3: ...3 ESPA OL www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es...

Page 4: ...26 EN T l chargez le guide de l utilisateur sur notre site Web sulion es ean 8426107054326 FR Baixe o guia do usu rio em nossa web sulion es ean 8426107054326 PT DE Laden Sie die Bedienungsanleitung i...

Page 5: ...miento del suministro el ctrico Espa ol 02 English 09 Instalaci n del ventilador Fan installation 13 ndice Indice Index1 Componentes Parts Repuestos Spares Herramientas requeridas Required tools Enhor...

Page 6: ...actores s lo pueden y deben ser aportados por el usuario que cuida y disfruta de este ventilador La instalaci n debe de ser realizada por personal cualificado para realizar instalaciones el ctricas de...

Page 7: ...do de espera W 0 5 Norma de medici n del valor de servicio EN 62879 2020 LED Potencia 20W Flujo 2000lm Temperatura de color 3000 4000 6000K RGB No Medici n datos luz 360 N de ciclos ON OFF 10000 N de...

Page 8: ...a del control remoto durante 10 segundos continuados 2 Un sonido de tipo beep indica que la conexi n ha sido ejecutada y el equipo puede funcionar normalmente 3 Ahora control remoto y receptores de lo...

Page 9: ...do tal y como se explica a continuaci n 3 Encienda el ventilador en la velocidad m s alta para que se produzca mayor balanceo 4 Apague el ventilador Seleccione un aspa y coloque el clip ver figura en...

Page 10: ...es de techo tienden a balancearse du rante su funcionamiento El balanceo de dos cent metros es totalmente aceptable y no sugiere ning n mal funciona miento ni originar su ca da si se mont siguiendo es...

Page 11: ...loor and 300 mm from any object or wall The mounting bracket must be attached to a ceiling structure that is capable of supporting a minimum of 30 kg using the two screws provided At least 30 mm of th...

Page 12: ...ours of lifespan 30000h Dimmable Yes Angle 120 CRI 80 This product have a light source of energy efficiency class F Fan Speed 6 Power W 21 RPM 200 Airflow m min 137 Airflow m h 8200 Max noise level dB...

Page 13: ...p sound indicates that the connection has been executed and the equipment can function normally 3 Now transmitter and receiver of the fan s will have been synchronized Turn off the fan s current using...

Page 14: ...to the highest speed so that the greatest amount of wobbling is produced 2 Turn off the fan Select a blade and place a clip on it see diagram halfway between the fastening and the far edge of the blad...

Page 15: ...operation A wobble of 2 cm is perfectly acceptable and does not indi cate any malfunction nor will it cause the fan to fall as long as it was mounted to the ceiling correctly following the instruction...

Page 16: ...16 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 100 120 1 2 3 4 5 1 2 Instalaci n ventilador Fan installation 01 02 04 06 03 05 07...

Page 17: ...ulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es 1 2 3 1 2 3 4 2 3 1 NO INCLUIDOS NOT INCLUDED OFF 1 2 70 Green Yellow B la c k Brown Blue G re e n Y e ll o w W h it e 08 10 12 14 09...

Page 18: ...18 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 Click 1 2 1 2 3 4 16 18 19 17 20...

Page 19: ...19 www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es ON ON 21...

Page 20: ...20 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 21: ...ards DECLARACI N DE CONFORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60598 1 2015 A1 2018 EN 60598 2 1 1989 EN 60335 1 2012 A11 2014 A13 2017 EN...

Page 22: ...www sulion es...

Reviews: