Congratulations on your purchase

Congratulations on your purchase of the latest in energy 

efficient ceiling fans.

Energy efficiency: 

SULION motors belong to the latest 

design technology in fans, saving up to 70% in energy 

consumption with DC motors.

Silent operation: 

Thanks to R&D advances in our motors, we 

have effectively reduced their operating noise in all models.

Comfort:

 DC motor fans include up to 6-speed remote 

control which provides superior comfort levels in their use. 

Safety precautions

Follow these instructions carefully to enjoy 

maximum safety in the installation and 

operation of this equipment.

The electrical installation of the ceiling fan must 

be carried out by an authorized electrician 

in order to be covered by our warranty. 

Please remember to require your installer to 

test all the fan functions before you leave. 

In case of any doubt from the installer, do not 

hesitate to contact us.

This device can be used by children aged 8 

years and above and people with reduced 

physical, sensory or mental abilities or lack 

of experience or knowledge, if they have 

been given appropriate supervision or training 

regarding the use of the device and they 

understand the dangers of its use. Children 

should not play with the device. The cleaning 

and maintenance of the device should not be 

carried out by children without supervision.

The fan must be installed in such a way that 

the blades are more than 2,3m above the 

ground. Make sure that there is a space of at 

least 30cm between the fan’s blades and any 

wall or other obstacle that they could hit. It is 

important to note that the greater the distance, 

the more efficient the air flow produced will 

be.

Any action performed for the electrical 

connection of the device, such as its cleaning, 

must be carried out after ensurin that the 

general power supply is disconnected, by 

removing the corresponding fuse or disarming 

the protective switch in order to ensure total 

isolation of the power supply. 

The system of attaching the fan bracket to the 

ceiling will depend on the type of ceiling where 

the installation is to be done. The decision 

on which attachment system to use and the 

quantity is the installer’s responsibility.

The fan must be installed at a location on 

the ceiling sch that the blades are at least 

2.3 m above the floor and 300 mm from any 

object or wall. The mounting bracket must be 

attached to a ceiling structure that is capable 

of supporting a minimum of 30 kg using the two 

screws provided. At least 30 mm of the length 

of the screws must be screwed into the bracket. 

When deciding where to mount the fan, be sure 

that there is at least 30 cm of space between the 

fan and any wall or other obstruction that the fan 

blades could collide with. The greater this distance, 

the more effective the air flow produced.After the 

fan is mounted, be sure that the blades are no less 

than 2.3 m above the ground

The ground wire of the fan must be connected to 

the earth network of the installation, to avoid any 

derivation that may put people in danger.

Do not connect the fan’s power supply to any 

dimmers, potentiometers, or light switches, as 

it will cause the fan to malfunction and/or will 

damage the motor. For the electrical connection it 

is necessary to incorporate a switch disconnector 

in accordance with the installation regulations, 

which ensures an omnipolar cut, directly 

connected to the power terminals and must 

have a contact separation at all its poles, which 

provides total disconnection under conditions of 

Category III overvoltage. The fan must be directly 

connected to a properly protected installation 

circuit (magnetothermal differential switch with 

the adequate size for the fan’s consumption and 

technical specifications). Only use the fan’s control 

to turn it on or stop it.

It is recommended to not use these types of fans 

along with gas installations simultaneously in the 

same room.

Do not insert anything that could hit the fan’s 

blades into its pathway while it is moving, as this 

could cause damage to people, can damage the 

blades, and can offset the balance of the unit, 

causing vibrations and wobbling.

 After installing the fan, ensure that all fastenings 

are secure and tightened in order to avoid any 

noise caused by loose elements.Due to the fan’s 

movement, certain fastenings may become loose. 

Check all fastenings twice per year at a minimum 

in order to ensure that they are sufficiently tight. If 

necessary, they must be retightened.

If the power cord is damaged, it must be replaced 

by the manufacturer, its after-sales service or 

similar qualified personnel in order to avoid any 

malfunction.

Only suitable for indoor. 

 Replaceable LED

 Replaceable driver

 Replaceable receiver and remote control

<8

Kg

OFF

OFF

Summary of Contents for 1005011

Page 1: ...de nuestra web www sulion es donde encontrar s un acceso a v deos instrucciones y una gu a de preguntas frecuentes In the event of any questions incidents or missing parts before consulting with your...

Page 2: ...2 ESPA OL Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540...

Page 3: ...3 ESPA OL www sulion es ATC 916749481 info sulion es SAT 916749483 sat sulion es...

Page 4: ...23 EN T l chargez le guide de l utilisateur sur notre site Web sulion es ean 8426107053923 FR Baixe o guia do usu rio em nossa web sulion es ean 8426107053923 PT DE Laden Sie die Bedienungsanleitung i...

Page 5: ...ilador Fan installation 13 ndice Indice Index1 Repuestos Spares Herramientas requeridas Required tools Pala Blade Ref 2171258 Kit receptor mando Kit receiver RC Ref 2171234 Filtro HEPA Ref 2171289 PCB...

Page 6: ...odr a provocar da os a las personas da ar las aspas y descompensar la unidad causando vibraciones y bamboleo Traselmontajedelventilador aseg resedeque todas las fijaciones est n seguras y apretadas Kg...

Page 7: ...x m seg 12 73m s Filtros Tipo de filtro 4 filtros de carb n activo Elimina part culas 0 3 Tipo de filtro 2 filtros HEPA Elimina part culas 0 3 Vida til del filtro h 3000h rea de aplicaci n m2 10m2 CA...

Page 8: ...trol remoto El control remoto y el receptor de este ventilador vienen sincronizados ya de f brica Aseg rese de que todas las conexiones est n correctamente realizadas Aseg rese de que el mando a dista...

Page 9: ...a balancearse du rante su funcionamiento El balanceo de dos cent metros es totalmente aceptable y no sugiere ning n mal funciona miento ni originar su ca da si se mont siguiendo este ma nual de forma...

Page 10: ...t be installed at a location on the ceiling sch that the blades are at least 2 3 m above the floor and 300 mm from any object or wall The mounting bracket must be attached to a ceiling structure that...

Page 11: ...not be used as a safety device in case of accidents involving combustion processes and hazardous chemicals The preset air purifying filters for this appliance are the highly efficient HEPA filter and...

Page 12: ...surement 360 Sphere N of ON OFF cycles 10000 N of hours of lifespan 30000h Dimmable Yes Angle 120 CRI 80 This product have a light source of energy efficiency class E Fan Speed 6 Power W 19 RPM 1200 A...

Page 13: ...wer wall switch of the fan or fans that you want to control and then just within the following 15 seconds press the key of the remote control for 3 continuous seconds 2 A beep sound indicates that the...

Page 14: ...wobble during their operation A wobble of 2 cm is perfectly acceptable and does not indi cate any malfunction nor will it cause the fan to fall as long as it was mounted to the ceiling correctly follo...

Page 15: ...ATC 916749481 info sulion es SAT 916749483 sat sulion es 100 100 70 70 2 2 1 1 3 NO INCLUIDOS NOT INCLUDED OFF L N 2 1 100 100 2 4 1 3 100 100 3 4 ON ON Instalaci n ventilador Fan installation 01 03 0...

Page 16: ...16 Calle Verano 51 Pol gono Industrial Las Monjas 28850 Torrej n de Ardoz Madrid ESPA A CIF A28763647 34 916774540 Cambio de filtros Filter cahnge 1 2 3 3 2 1 02 01...

Page 17: ...ORMIDAD CE DECLARATION OF CONFORMITY Madrid 05 11 2021 C Schuller CEO RED 2014 53 EU Article 3 1a EN 60598 1 2015 A1 2018 EN 60598 2 1 1989 EN 60335 1 2012 A11 2014 A13 2017 EN 60335 2 80 2003 A1 2004...

Page 18: ...www sulion es...

Reviews: