sugar-valley BIONET Quick Instalation Manual Download Page 3

Electronic housing display

ALARM

Excessive increase or decrease in parameters (+/- 15% 
from the selected parameters).
CHECK LEVELS IN ACID/BASE CONTAINERS
CHECK PROBE CALIBRATION

WORN ELECTRODES or low conductivity

The  production  level  shown  presently  on  screen 
corresponds to less than 50% of the preselected level. 
Electrodes may be worn or water conductivity low.

Insufficient FLOW or cell disconnected

Production  halted  due  to  lack  of  flow,  or  gas  in  the 
titanium cell detector.

ONLY SYSTEMS WITH FREE CHLORINE CONTROL 
(ppm's)
INSUFFICIENT FLOW in the CHLORINE detector.

The rotary sensor detects insufficient flow. CHECK the 
rotameter  pendel  –  and  solve  the  system's  hydraulic 
problem  (If  there  is  a  preceding  filter  this  must  be 
cleaned).

Conductivity/Cell life

Low conductivity (See section 3)
Titanium cell incrusted 

(See cleaning process in section 5)

Cell surface corroded (See section 7)

ONLY SYSTEMS WITH REDOX OR FREE CHLORINE

The system has automatically stopped as Redox levels 
are above the chosen values (See section 5)

Time delay

Period of non-production while system changes polarity 
(0-120 sec.)

IONIZATION INTERVAL PROGRAMMER

The  system  is  programmed  to  ionize  for  a 
predetermined period each time it is started up:
Pr--  : Will run continually.
Pr30: Will run for 30 min. following start up.
Pr60: Will run for 60min. following start up.
Pr90: Will run for 90min. following start up.

Status led's
Electrolysis production

ENTER button
Right button
Left button

START UP

4

INITIAL ADJUSTMENTS

3

Water adjustments

1.Adjust the alkalinity between 90 and 110 ppm.
2.Adjust the PH between 7,2 and 7,4
3.Adjust the chlorine between 1 and 1,5 ppm.

SHOULD the water be supplied from a well: shock 
chlorinate with Tricloroisocyanuric acid (2Kg./50m3 
of water)

Adding Salt to the Water

Start up

ADD 5 TO 6 GRAMM SALT (WITHOUT YOD) FOR EACH LITRE OF WATER 
IN YOUR SWIMMING POOL (5 to 6 kg NaCl per m3 Water). Open the bottom 
valve of your swimming pool and add the Salt directly to your swimming pool 
water. Let the circulation pump run during the first 24 hours your BIONET 
SYSTEM  IS  WORKING  in  order  to  dissolve  the  Salt  completely.  Your 
BIONET System will operate without any problems with salt concentrations 
from 2,5g to 50g Salt per litre.

 IN POOLS WHICH RECEIVE LARGE AMOUNTS OF STRONG SUNLIGHT 
40gr/m3 OF STABILYSER (Isocyanuric acid) MUST BE ADDED

Up button

Down button

Ionization

pH Probe

Conductivity probe/
water temperature

Free Chlorine/Redox

Summary of Contents for BIONET

Page 1: ...ing 1 2 3 Probe Probe casing Connection housing 1 2 3 1 2 3 1 2 3 1 2 3 1 3 3 2 4 5 6 10 7 8 9 6 1 2 3 4 5 11 10 1 4 5 2 3 5 4 The salt water electrolysis produces Chlorine on the bases of salt water of low salinity approximately 5g Salt per litre As the swimming pool water containing the salt flows through the electrolysis cell the salt is converted to Sodium hypo chloride liquid chlorine Organic...

Page 2: ...when water circulation has stopped TITANIUM CELLconnection overheating Ensure all electrical connections are firmly fixed to avoid false contacts and subsequent overheating of system components Especially concerning the electrolysis cell with usage above 33A 10A 10A 16A 16A 25A A B C 1 2 3 4 5 6 15 13 12 11 10 9 8 min 1m 330W 10A Chlorine pump Optional for models with redox or free chlorine contro...

Page 3: ...ERVALPROGRAMMER The system is programmed to ionize for a predetermined period each time it is started up Pr Will run continually Pr30 Will run for 30 min following start up Pr60 Will run for 60min following start up Pr90 Will run for 90min following start up Status led s Electrolysis production ENTER button Right button Left button START UP 4 INITIAL ADJUSTMENTS 3 Water adjustments 1 Adjust the al...

Page 4: ...OVE INCRUSTATIONS Scratching the edges or surface of the cell will make it vulnerable to chemicals deteriorate the cell and annul the guarantee Titanium cell maintenance During the first 10 15 days your pool system will require more attention and the following care 1 During the Use of the Ionizer it is important not to exceed copper concentrations of more than 0 5 PPM in the water For this reason ...

Page 5: ... increase pH minimum water pH CONTROLS THE base PUMP optional equipment pH PROBE CALIBRATION Insert probe in pH 7 sample wait till reading has stabilized RECOMMENDED LEVEL 6 8 RECOMMENDED LEVEL 7 2 7 5 Clean probe in NEUTRAL Insert probe in pH 10 sample and wait till reading is stable Calibration correct Repeat calibration or change probe Redox SET POINT To modify parameters Redox set point To con...

Page 6: ...ion 3 water preparation Check for incrustations on cell See troubleshooting Hydrolysis does not reach maximum intensity White flakes in pool This happens in excessively hard unbalanced waters Balance the water and check the cell proceeding to clean it if necessary Hydrolysis display shows FL Check flow detector cable Clean incrustations of flow detector at top of cell casing Check system is free o...

Reviews: