EN 4/6
SUEVIA HAIGES GmbH • Max-Eyth-Str. 1 • 74366 Kirchheim am Neckar • Deutschland • Tel. +49 7143 971-0 • Fax +49 7143 971-80
www.suevia.com • [email protected] • Stand: 30.05.2015
2.4 Setting the gap for the proximity switch
The gap between proximity switch and counter-magnet should be approx.
20mm.
Figure 6:
Proximity switch and counter-magnet
3.
Exchanging the brushes
Note:
The brushes are to be exchanged at your discretion. Replacement is
indicated, however, when the shortest bristles at less than 5cm long.
Figure 7:
Overview of brush replacement
3.1 Replacing the upper brush
Procedure, (see Figure 8):
• Remove the screw (Pos. 1).
• Take off the disc (Pos. 2).
• Pull the brush from the square section (Pos. 3)
Figure 8:
Mounting the upper brush
3.2 Replacing the lower brush
Procedure (see Figure 9):
• Remove the screws (Pos. 1) on the left and right.
• Loosen the 2 threaded pins on the flanged bearing.
• Pos. 2 can now be removed together with the lower bearing.
• Remove the locking ring (Pos. 3).
• Pull the brush off the square section (Pos. 4).
Figure 9:
Mounting the lower brush
4.
Maintenance
•
Check once a month that all screws are tight. Retighten the screws
if necessary.
•
Re-grease the slide, if necessary.
•
Please use normal everyday cleaning agents.
•
Never use solvents, acids or caustic agents for cleaning purposes.
•
Gear oil: SAE 90 API GL5
Pos. 1
Pos. 4
Pos. 3
Pos. 2
Pos. 1
Pos. 2
Pos. 3
ENGLISH