SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
International models from the factory designed without a
transformer require a 220-240 V AC, 50/60 Hz electrical
supply, fused at the correct rating for the unit. If required
by local or national codes, the power cord can be easily
replaced using the power inlet device.
Locate the electrical supply within the shaded area shown
in the illustration below. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Power Supply
220-240 V AC, 50/60 Hz
Circuit Breaker
10 amp
Receptacle
grounding-type (earthed)
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must not
interfere with the installation of the anti-tip bracket.
A reverse osmosis system can be used provided there
is constant water pressure of 2.4–8.3 bar supplied to the
unit at all times. A copper line is not recommended for this
application.
PLUMBING REQUIREMENTS
Water Supply
6.4 mm OD copper line,
braided stainless steel, or PEX tubing
Water Pressure
2.4–8.3 bar
Excess Water Line for Connection
.9 m
1918 mm
FROM FLOOR
178
mm
E
152
mm
RIGHT SIDE
OF OPENING
Electrical supply location
76 mm
152
mm
132
mm
RIGHT SIDE
OF OPENING
AREA EXTENDS 13 mm
FORWARD ON FLOOR
Water supply location