background image

FOR YOUR SAFETY READ 

BEFORE OPERATING

WARNING!

 

If the user of this appliance fails to maintain it 

in the condition in which it was shipped from the factory or 

if the appliance is not used solely for its intended purpose 

or if appliance is not maintained in accordance with the 

instructions  in  this  manual,  then  the  risk  of  a  fire  and/or 

the production of carbon monoxide exists which can cause 

personal injury, property damage or loss of life.

OPERATING INSTRUCTIONS

WARNING!

 

If you do not follow these instructions exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

WARNING!

 

Before operating water heater, be sure tank is filled with water.  See “Safety Warnings”.

A

.  This appliance does not have a pilot. It is equipped with an ignition device 

which automatically lights the burner. Do not try to light the burner by hand.

B. 

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to 

smell next to the floor because some gas is heavier than air and will settle on 

the floor.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electric switch.

•  Do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas 

supplier’s instructions.

• 

If you cannot reach your gas supplier, call the fire department.

C.  

This is an automatic gas valve, no adjustments are necessary. Do not attempt 

to repair the gas valve. This may result in a fire or explosion.

D.  

Do not use this appliance if any part has been under water. Immediately call 

an authorised service technician to inspect the appliance and to replace any 

part of the control system and any gas control which has been under water.

E.  

Before operating water heater, check the location of the vent to make sure 

it will not be blocked by the opening of any door on the trailer. If it can be 

blocked, do not operate the water heater with the door open.

OPERATING INSTRUCTIONS

1.

  STOP! Read the safety information provided.

2.

  Turn off all electric power to the appliance.

3. 

Turn “OFF” gas supply.

4. 

Wait five minutes for gas to clear the area. If you smell gas then STOP! Follow instruc

-

tions in item B of the safety information. If you don’t smell gas, go to next step.

5. 

Turn “ON” gas supply.

6.

  Turn on 12 volt electrical power to the appliance.

7.

  Turn switch to “ON” position. If the burner does not light, the system will auto-

matically attempt two more tries for ignition before lockout. See Figure 8A.

NOTE

: Each ignition cycle will have a 15 second purge before spark cycle if sys-

tem is a three try system.

8.

  If lockout occurs before main burner lights, turn switch to “OFF”, wait five sec

-

onds and turn switch to “ON” position. This will restart the ignition cycle. The 

first start-up of the heater may require several ignition cycles before all air is 

purged from the gas lines.

If the burner will not come on, the following items should be checked before calling 

a service person.

1. 

Switch turned off.

2.

 Gas supply to heater is empty or turned off.

3. 

Reset button on ECO is tripped

OPERATING INSTRUCTIONS

 FOR UNITS WITH ELECTRIC ELEMENT

Electric water heaters are designed to operate with a minimum amount of service 

problems; however, proper operation and care is essential.
By far the most common trouble with electric water heaters results from energizing 

the water heater before it is filled with water. 
Turn off gas supply to the water heater. To energize the electric heating element, 

turn the circuit breaker to “ON.” Reverse the procedure to disconnect electric heat-

ing element.

TO TURN OFF WATER HEATER

1. 

Turn switch to “OFF” position.

2. 

Turn off circuit breaker to the appliance.

3. 

Turn off gas supply.

4.

  If vehicle is to be stored or heater is going to be turned off while subject to 

freezing temperature, drain water heater. (See “Draining and Storage Instruc-

tions.”) 

TROUBLESHOOTING GUIDE

FRAMING

A

B

INNER COACH WALL

OUTER COACH WALL

FLOORING

A=325 MM + 3MM - 0

B=325 MM + 3MM - 0

Figure 1

SECURE CHOCKS, ONE ON EACH SIDE, TIGHTLY AGAINST WATER HEATER JACKET

AND FASTEN TO VEHICLE FLOOR TO PREVENT MOVEMENT. CHOCKS SHOULD BE

APPROXIMATELY 2" X 2" X 6"  

FRAMED OPENING

COMPARTMENT

BOTTOM

Figure 1A

5

Summary of Contents for SW4DEFA

Page 1: ...H ANY ELECTRICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING OR RV IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBORS PHONE FOL LOW THEIR INSTRUCTIONS FREEZE WARNING DRAIN HEATER IF SUBJECTED TO FRE...

Page 2: ...ion heater into framed opening as illustrated D On mesa or yoder type sidewalls flatten the wall area around the opening E Caulk around framed opening trailer skin as illustrated F Apply a bead of sil...

Page 3: ...connections are tight and in compliance with codes See Making Electrical Connections D The following is information regarding Hot Water Services and corrosion of the tank in Australia The single bigg...

Page 4: ...om the valve until it stops 5 Release handle on P T Valve it should snap closed 6 Close tap and turn on cold water supply as the tank fills the air pocket will develop Repeat this procedure as often a...

Page 5: ...provided 2 Turn off all electric power to the appliance 3 Turn OFF gas supply 4 Wait five minutes for gas to clear the area If you smell gas then STOP Follow instruc tions in item B of the safety info...

Page 6: ...EAL DOOR FRAME TO SKIN WATER TIGHT SEE DETAIL A Figure 2B Models SW4DRA and SW6DRA Figure 2A Models SW4DERA and SW6DERA A FRAMED OPENING DETAIL A SPECIAL SCREW CONTROL HOUSING GASKET DOOR LATCH RADIUS...

Page 7: ...S FRAME TO COACH WALL FLUSH MOUNT DOOR FRAME A INTERMEDIATE FRAME WITH GASKET FRAMED OPENING DETAIL A SPECIAL SCREW CONTROL HOUSING GASKET CONTROL HOUSING GASKET OR CAULK AROUND OPENING TO SEAL CONTRO...

Page 8: ...CTORY WIRING FIELD WIRING DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT AND HI LIMIT UNDER ACCESS COVER 1 3 4 6 CAUTION DO NOT HI POT DIELECTIC HIGH VOLTAGE TEST THIS UNIT AFTER INSTALLATION TO...

Page 9: ...ILL NOT COME ON NOT ENOUGH HOT WATER WATER TOO HOT POSSIBLE CAUSE XXXXX Possible malfunction of the bottled gas regulator XXXXX Main burner orifice too small or clogged XXXXX Check thermostat position...

Page 10: ...7 6 27 42 28 59 6 63 47 38 10 12 13 13 13 13 13 13 66 66 66 Figure 12 SW4DERA AND SW6DERA SW4DEFA AND SW6DEFA MODEL SERIAL NO PLATE 12 20 21 53 26 39 35 38 34 37 55 56 36 45 41 29 50 51 1 3 52 15 8 4...

Page 11: ...ment with Gasket 520831 29 Anode 233514 31 Connector Electric Gas valve wire 521264 34 Gas Fitting 170374 35 Bracket Valve Mounting 063243 36 Valve Gas LP 161164 37 Manifold Outlet 171420 38 Screw 8 x...

Page 12: ...y or diagnosis without repair 3 Damage or repairs required as a consequence of faulty or incorrect installation or application not in conformance with installation instructions 4 Failure to start or o...