background image

OPERATING INSTRUCTIONS

1.  STOP! 

Read Users Information Manual supplied with furnace.

2.  

Turn the manual valve (if so equipped) or the valve at the outside LP tank to the “OFF” position. Do not force.

3.  

Set thermostat above room temperature to begin blower operation. A slight delay will occur before the blower comes on. Allow 

blower to run for 5 minutes for combustion chamber purge cycle. 

If blower does not come on or stops before ignition cycle, go to shut down   and contact your dealer or a local recreational vehicle 
service agency.

4.  

After 5 minutes, move thermostat lever below room temperature. Blower will remain on. Wait approximately 2 minutes for blower 

to go off.

5.  

Wait five (5) minutes to clear out any gas. Then smell for gas including near  the floor. If you then smell gas, 

STOP!

 Follow “B” 

in the safety information  above on this label. If you don’t smell gas, go to next step.

6.  

Open manual shut-off valve or the valve at the outside LP tank. Correct operating characteristics depend on the valve being 

positioned fully open. Never attempt to operate with a valve partially closed.

NOTE: 

Furnace Models NT-16SQ and NT-20SQ are equipped with a valve shut-off switch, with switch in “OFF” position, gas will 

not flow through to burner nor will the furnace operate.

7.  

Set thermostat lever to desired setting. If set above room temperature, blower will come on.

8.  

Allow 30 seconds for main burner to light after blower comes on. This furnace  Is equipped with an ignition device which 

automatically lights the burner. Do not try to light the burner by hand.

9.  

If burner does not light, repeat Steps 1 through 9.

10.  

If after  three  (3)  attempts  with  no  ignition,  go  to  shut  down  and  contact  your  dealer  or  a  local  recreational  vehicle  service 

agency. Do not continue to cycle furnace through thermostat in an attempt to get ignition.

TO TURN OFF GAS TO APPLIANCE

1.

Set the thermostat to lowest setting, then move lever to “OFF” position.

2.

Turn off all electric power to the appliance if service is to be performed.

3.

Turn shut-off valve clockwise 

 to “OFF”. Do not force.

MANUAL SHUT OFF VALVE

VALVE D ARRET MANUEL

HANDLE IN "OFF" POSITION

MANETTE DANS LA POSITION ARRET (OFF)

VALVE SHOWN IN "OFF" POSITION

VALVE MONTREE DANS LA POSITION D ARRET (OFF)

NOTE: VALVE SHOW ABOVE  IN “OFF” POSITION.

5