7
Troubleshooting
●
Adjustment of Coin Selector
When reading Coins/ Tokens with wrong, please do the adjustment of Coin Selector. The Coin
Selector of this machine used the electronic Coin Selector. Please adjust the sensitivity of Coins/
Tokens.
Insert Coin/ Token
a. Open the door of main cabinet.
19
b. Turn power ON.
c. Install the standardized Coin/ Token which has been used
at the store into the Coin/ Token identification unit of Coin
Selector.
The machine used electronic Coin Selector. It doesn’t
recognize the type of Coin/ Token other than Coin/ Token
which is installed. Please remove if the multi types of
Coin/ Token have mixed.
d. When reading Coins/ Tokens with wrong, please turn
“Adjust Sensitivity Volume” (VR Tuning) and to make the
sensitivity with a little slack. (Please note that when the
sensitivity is made slack too much, it will mix the Coins/
Tokens of other stores.)
e. Throwing several coins/ tokens into Coin Selector, and
adjust a state where it doesn’t reject the coins/ tokens.
Adjust Sensitivity Volume
Turn Right=Slack
Turn Left=Tight
f. After adjust and check, close the door of main cabinet.