CAUTION

Notice: 

The  information  in  this  document  is

 

subject

 

  to 

change  in  order  to  improve  reliability  ,  design  or  function 
without prior notice and does not represent

 

a commitment on 

the  part  of  the  company.  In  no

 

event  will  the  company  be 

liable for direct, indirect, special, incidental or consequential 
damage arising out of the use or inability to use the product 
or documentation, even if advised of the possibility of such 
damages.  No  part  of  this  manual  may  be  reproduced  or 
transmitted in any form or by any means without the prior 
written permission of the company.

WIRING:

 The probe and its corresponding wires should

 

never be 

installed in a conduit next to control or power

 

supply lines. The 

electrical wiring should be done as shown in the diagram. The 
power supply circuit should be connected to a protection switch. 
The terminals admit wires of upto 2.5sq mm.

WARNING:

  Improper wiring may cause irreparable damage and 

personal  injury.  Kindly  ensure  that  wiring

 

is  done  by  qualified 

personnel only.

Maintenance:

 Cleaning:  Clean the surface of the controller with 

a soft moist cloth. Do not use abrasive detergents, petrol, alcohol 
or solvents.

19

Display  

3

 

X14.2 mm (0.56") LED

Housing

  

:

  White, ABS Plastic

Front Cover

  

:

  Red Polycarbonate plastic.

Light Relay   :

  5A, 250Vac(res.)

O

O

Resolution :

 1 C / 0.1 C.

 

   

<

 2.5sqmm one wire/terminal only

O

O

O

Range  

:

  -40 C to 99 C (1 C).

O

Accuracy :

 +/- 1 C.

Power input  :

  230Vac

 

+/-15%,50-60Hz.

Input  

:

  NTC probe, SZ-N75.

Compressor Relay :

 8

 

(3)A, 250Vac.

Connections :  

Screw terminal blocks. 

 

  Other on request.

Dimensions  :

  Front 

:

 80  X  126 mm,

 

  Depth

 :

 15 mm.

O

O

Probe tolerance at  25 C

 

:

 +/- 0.3 C.

Mounting  

:

  Wall Mount.

Technical data:

Data storage :  

Non-volatile EEPROM memory

O

O

Storage temp :

 -20 C to 70 C(non-condensing).

Output : 

O

O

Operating temp. :

  5 C to 50 C(non-condensing).

O

O

O

              

  -40.0 C to 50.0 C (0.1 C).

20

NEUTRAL

To SZ-N75

Compressor

, Contactor

or Heater 8(3)A

 max

PHASE

Caution:Wiring for 230Vac load only

10

8

9

11

7

230V

1

NC NO

C

PROBE

6

COMP

5

4

C

NO

NC

3

LIGHT

Light 250V

AC, 5A(res.)

FRONT VIEW

21

17

Operating messages and Icon status

Parameter

Message Description

P2

Ht

Temperature above the maximum 
limit of the set point. 

P3

Lt

Temperature below the minimum limit 
of the set point.

PP

Probe short circuit, circuit open or without

0

0

 

probe, or temperature > 99 C or <-40 C

0

when RS=1 and temperature >50.0 C or

0

<-40.0 C when RS=0.

SP, P4

Comp. Relay ON/OFF.

On/Off

LP

Keypad locked/unlocked

On/Off

P6

Time delay in progress

Flashing

Light Relay ON/OFF.

On/Off

18

Power Key

Used to switch ON the controller.

Set Key

UP Key

Used in program mode and set mode 
to increment parameter value.

Down Key /
Program Key

Used to enter into the program mode.

Key Introduction

Also used as Down key to decrement  
parameter value in program mode.

Used  in program mode to set/save the 
changed value of parameter.

If press UP key once Light Relay & LED 
will become ON and If press again once 
Light Relay & LED will become OFF.